The performance and strategies used in electron reconstruction and selection at CMS are presented based on data corresponding to an integrated luminosity of 19.7 fb-1, collected in proton-proton collisions at √s = 8 TeV at the CERN LHC. The paper focuses on prompt isolated electrons with transverse momenta ranging from about 5 to a few 100 GeV. A detailed description is given of the algorithms used to cluster energy in the electromagnetic calorimeter and to reconstruct electron trajectories in the tracker. The electron momentum is estimated by combining the energy measurement in the calorimeter with the momentum measurement in the tracker. Benchmark selection criteria are presented, and their performances assessed using Z, , and J/ψ decays into e+ + e- pairs. The spectra of the observables relevant to electron reconstruction and selection as well as their global efficiencies are well reproduced by Monte Carlo simulations. The momentum scale is calibrated with an uncertainty smaller than 0.3%. The momentum resolution for electrons produced in Z boson decays ranges from 1.7 to 4.5%, depending on electron pseudorapidity and energy loss through bremsstrahlung in the detector material.

Performance of electron reconstruction and selection with the CMS detector in proton-proton collisions at √s = 8 TeV

ALBERGO, Sebastiano Francesco;CAPPELLO, GIGI;CHIORBOLI, MASSIMILIANO;COSTA, Salvatore;GIORDANO, FERDINANDO;POTENZA, Renato Carlo;TRICOMI, Alessia Rita;TUVE', Cristina Natalina;
2015-01-01

Abstract

The performance and strategies used in electron reconstruction and selection at CMS are presented based on data corresponding to an integrated luminosity of 19.7 fb-1, collected in proton-proton collisions at √s = 8 TeV at the CERN LHC. The paper focuses on prompt isolated electrons with transverse momenta ranging from about 5 to a few 100 GeV. A detailed description is given of the algorithms used to cluster energy in the electromagnetic calorimeter and to reconstruct electron trajectories in the tracker. The electron momentum is estimated by combining the energy measurement in the calorimeter with the momentum measurement in the tracker. Benchmark selection criteria are presented, and their performances assessed using Z, , and J/ψ decays into e+ + e- pairs. The spectra of the observables relevant to electron reconstruction and selection as well as their global efficiencies are well reproduced by Monte Carlo simulations. The momentum scale is calibrated with an uncertainty smaller than 0.3%. The momentum resolution for electrons produced in Z boson decays ranges from 1.7 to 4.5%, depending on electron pseudorapidity and energy loss through bremsstrahlung in the detector material.
2015
Calibration and fitting methods, cluster finding, Pattern recognition, Performance of High Energy Physics Detectors, Instrumentation, Mathematical Physics.
File in questo prodotto:
File Dimensione Formato  
_2015_J._Inst._10_P06005 (1).pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Dimensione 1.97 MB
Formato Adobe PDF
1.97 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/310418
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 389
  • ???jsp.display-item.citation.isi??? 432
social impact