A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC . The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is 99.95 ± 0.05%, while the intrinsic spatial resolutions are 4.80 ± 0.25 μm and 7.99 ± 0.21 μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.

Test beam performance measurements for the Phase i upgrade of the CMS pixel detector

CARIOLA, PIETRA;FIORE, Lucia;SALA, Guido;Albergo, S.;Cappello, G.;Costa, S.;Mattia, A. Di;Giordano, F.;Potenza, R.;Tricomi, A.;Tuve, C.;TOSI, MARIA CHIARA;KHALED MOHEYELDIN, AHMED ISMAIL;TROPEA, PIERO;JOHNSON, Gavonni Mark;MARTIN, BRUNO JEAN CLODE;D'ANGELO, MARIA PROVVIDENZA RITA;
2017-01-01

Abstract

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC . The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is 99.95 ± 0.05%, while the intrinsic spatial resolutions are 4.80 ± 0.25 μm and 7.99 ± 0.21 μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
2017
Particle tracking detectors (Solid-state detectors), Radiation-hard detectors, Solid state detectors, Instrumentation, Mathematical Physics.
File in questo prodotto:
File Dimensione Formato  
Dragicevic_2017_J._Inst._12_P05022.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Dimensione 1.35 MB
Formato Adobe PDF
1.35 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/323166
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact