Objectives The authors sought to identify and verify independent correlates of device thrombosis from an analysis of multicenter trials and registries. Background Recent analyses suggest an increased risk of device thrombosis with Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, California) implantation compared with metallic drug-eluting stents, and data from moderate size studies suggest a risk relationship to vessel size and technique. Methods From 8,771 consecutively treated patients, 105 patients (1.2%) were identified with scaffold thrombosis within 1 year of implantation. They were matched 2:1 with controls selected randomly from nonthrombosis patients. Data-restricted multiple logistic analysis was used to identify significant independent covariates of the outcome. Results Early (within 1 month) scaffold thrombosis occurred in 69 patients and late (1 to 12 months) thrombosis occurred in 36 patients. Modelling found significant correlations of thrombosis to be final minimal lumen diameter <1.85 mm (odds ratio [OR]: 3.1; p = 0.004), off dual antiplatelet therapy (DAPT) status (OR: 3.1 to 3.5; p = 0.006 to 0.053), no post-dilatation with >1.1:1 balloon/scaffold ratio (OR: 2.3; p = 0.022), and reference vessel diameter <2.40 mm (OR: 2.1; p = 0.036). Conclusions Suboptimal vessel sizing, procedural technique, angiographic outcomes, and dual antiplatelet therapy discontinuation appear to be the principal determinants of Absorb scaffold thrombosis risk through 12 months after implantation.

Clinical, Angiographic, and Procedural Correlates of Acute, Subacute, and Late Absorb Scaffold Thrombosis

Tamburino, Corrado;
2017-01-01

Abstract

Objectives The authors sought to identify and verify independent correlates of device thrombosis from an analysis of multicenter trials and registries. Background Recent analyses suggest an increased risk of device thrombosis with Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, California) implantation compared with metallic drug-eluting stents, and data from moderate size studies suggest a risk relationship to vessel size and technique. Methods From 8,771 consecutively treated patients, 105 patients (1.2%) were identified with scaffold thrombosis within 1 year of implantation. They were matched 2:1 with controls selected randomly from nonthrombosis patients. Data-restricted multiple logistic analysis was used to identify significant independent covariates of the outcome. Results Early (within 1 month) scaffold thrombosis occurred in 69 patients and late (1 to 12 months) thrombosis occurred in 36 patients. Modelling found significant correlations of thrombosis to be final minimal lumen diameter <1.85 mm (odds ratio [OR]: 3.1; p = 0.004), off dual antiplatelet therapy (DAPT) status (OR: 3.1 to 3.5; p = 0.006 to 0.053), no post-dilatation with >1.1:1 balloon/scaffold ratio (OR: 2.3; p = 0.022), and reference vessel diameter <2.40 mm (OR: 2.1; p = 0.036). Conclusions Suboptimal vessel sizing, procedural technique, angiographic outcomes, and dual antiplatelet therapy discontinuation appear to be the principal determinants of Absorb scaffold thrombosis risk through 12 months after implantation.
2017
Absorb; bioresorbable scaffold; thrombosis; Acute Disease; Aged; Angioplasty, Balloon, Coronary; Clinical Trials as Topic; Coronary Thrombosis; Drug Therapy, Combination; Female; Humans; Logistic Models; Male; Middle Aged; Multivariate Analysis; Odds Ratio; Platelet Aggregation Inhibitors; Predictive Value of Tests; Proportional Hazards Models; Prosthesis Design; Registries; Risk Factors; Time Factors; Treatment Outcome; Absorbable Implants; Coronary Angiography; Cardiology and Cardiovascular Medicine
File in questo prodotto:
File Dimensione Formato  
Clinical, Angiographic, and Procedural Correlates of Acute, Subacute, and Late Absorb Scaffold Thrombosis.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Dimensione 660.56 kB
Formato Adobe PDF
660.56 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/336194
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 23
social impact