Surface substrate and chemical functionalization are crucial aspects for the fabrication of the sensitive biosensor based on microarray technology. In this paper, an advanced, silicon-based substrate (A-MA) allowing enhancement of optical signal for microarray application is described. The substrate consists in a multilayer of Si/Al/SiO2 layers. The optical signal enhancement is reached by a combination of the mirror effect of Al film and the SiO2 thickness around 830 nm, which is able to reach the maximum of interference for the emission wavelength of the Cy5 fluorescent label. Moreover, SiO2 layer is suitable for the immobilization of single-strand DNA through standard silane chemistry, and probe densities of about 2000 F/um2 are reached. The microarray is investigated in the detection of HBV (Hepatitis B Virus) pathogen with analytical samples, resulting in a dynamic linear range of 0.05–0.5 nM, a sensitivity of about 18000 a.u. nM−1, and a Limit of Detection in the range of 0.031–0.043 Nm as a function of the capture probe sequence.

An advanced, silicon-based substrate for sensitive nucleic acids detection

Petralia, Salvatore;Vicario, Nunzio;Calabrese, Giovanna;Parenti, Rosalba;Conoci, Sabrina
2018-01-01

Abstract

Surface substrate and chemical functionalization are crucial aspects for the fabrication of the sensitive biosensor based on microarray technology. In this paper, an advanced, silicon-based substrate (A-MA) allowing enhancement of optical signal for microarray application is described. The substrate consists in a multilayer of Si/Al/SiO2 layers. The optical signal enhancement is reached by a combination of the mirror effect of Al film and the SiO2 thickness around 830 nm, which is able to reach the maximum of interference for the emission wavelength of the Cy5 fluorescent label. Moreover, SiO2 layer is suitable for the immobilization of single-strand DNA through standard silane chemistry, and probe densities of about 2000 F/um2 are reached. The microarray is investigated in the detection of HBV (Hepatitis B Virus) pathogen with analytical samples, resulting in a dynamic linear range of 0.05–0.5 nM, a sensitivity of about 18000 a.u. nM−1, and a Limit of Detection in the range of 0.031–0.043 Nm as a function of the capture probe sequence.
2018
Biosensors; Microarray; Nucleic acids detection; Silicon; Analytical Chemistry; Atomic and Molecular Physics, and Optics; Biochemistry; Instrumentation; Electrical and Electronic Engineering
File in questo prodotto:
File Dimensione Formato  
Petralia_sensors_2018.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Dimensione 2.68 MB
Formato Adobe PDF
2.68 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/357701
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact