The development of environmentally-friendly methods as alternatives to chemical fumigation for controlling insect pests has attracted public attention. Among these methods, heat treatment is based on the use of fan heaters that are positioned by operators who typically establish their number and position within buildings to be treated. The aim of this research was to improve heat treatment effectiveness by applying a validated computational fluid dynamics (CFD) model for planning fan heater positions within the building environment. Based on a CFD model, which was built and validated according to experimental data acquired during heat treatment of a flour mill, simulations were carried out by changing the position and/or rotation of fan heaters with the aim of enhancing temperature distribution inside the building. The results showed that in some simulations the percentage of internal wall surfaces having a temperature value lower than that required for heat treatment efficacy was considerably reduced, by up to 56.7%. Therefore, the CFD approach proposed in this study could be used as a decision support system for improving heat treatment efficacy.

Application of a CFD validated model to plan fan heater position within flour mills during a heat treatment for insect pest control

Valenti, Francesca;Tomasello, Nicoletta;Lanteri, Paolo;Porto, Simona M. C.
2018-01-01

Abstract

The development of environmentally-friendly methods as alternatives to chemical fumigation for controlling insect pests has attracted public attention. Among these methods, heat treatment is based on the use of fan heaters that are positioned by operators who typically establish their number and position within buildings to be treated. The aim of this research was to improve heat treatment effectiveness by applying a validated computational fluid dynamics (CFD) model for planning fan heater positions within the building environment. Based on a CFD model, which was built and validated according to experimental data acquired during heat treatment of a flour mill, simulations were carried out by changing the position and/or rotation of fan heaters with the aim of enhancing temperature distribution inside the building. The results showed that in some simulations the percentage of internal wall surfaces having a temperature value lower than that required for heat treatment efficacy was considerably reduced, by up to 56.7%. Therefore, the CFD approach proposed in this study could be used as a decision support system for improving heat treatment efficacy.
2018
Computational fluid dynamics (CFD); Heat flux; Heat treatment; Milling industry; Thermal behavior; Architecture2300 Environmental Science (all); Civil and Structural Engineering; Building and Construction
File in questo prodotto:
File Dimensione Formato  
Buildings-08-vallidation.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Dimensione 4.09 MB
Formato Adobe PDF
4.09 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/362486
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact