A low-concentration static collector has been designed and manufactured. The chosen geometry reduces the thermal convection, while the selective coating of the absorber reduces radiative losses. The total thermal losses have been measured as a function of temperature difference between absorber and ambient up to ΔT=150°C. A tipical loss figure obtained is 160 W/m2 at ΔT=80°C. © 1979 Societá Italiana di Fisica.

Heat losses of a static low-concentration solar collector

Musumeci F.;Triglia A.
1979-01-01

Abstract

A low-concentration static collector has been designed and manufactured. The chosen geometry reduces the thermal convection, while the selective coating of the absorber reduces radiative losses. The total thermal losses have been measured as a function of temperature difference between absorber and ambient up to ΔT=150°C. A tipical loss figure obtained is 160 W/m2 at ΔT=80°C. © 1979 Societá Italiana di Fisica.