A rapid, selective and sensitive method for quantification of latanoprost free acid in rabbit aqueous humor (AH) and ciliary body (CB) using reverse phase-high performance liquid chromatography coupled with electrospray ionization (ESI)-mass spectrometry/mass spectrometry has been developed and validated. Quantification in AH and CB was achieved by stable isotope dilution employing tetra-deuterated analog of latanoprost free acid, used as internal standard. Sample preparation was based on protein precipitation with methanol in AH, and on liquid extraction with a mixture of ethyl acetate and isopropanol 60:40 (v/v) in CB. Elution was achieved on an octylsilica (C8) column, using an isocratic elution method. Detection was performed on a triple quadrupole mass spectrometer, using ESI in positive ion selected reaction monitoring mode. Calibration curves were linear in the validated concentration ranges of 10-160 ng/mL in AH and 80-1280 ng/g in CB. The accuracy and precision values, obtained from three different sets of quality control samples, each analyzed in triplicate on three different days, were within the generally accepted criteria for analytical methods (< 15%). The limit of detection was 30.66 pg/mL in AH and 237.75 pg/g in CB. The assay proved to be accurate and precise when applied to the in vivo study of latanoprost free acid in rabbit AH and CB after single administration of an eye drops containing latanoprost.

DEVELOPMENT AND VALIDATION OF A LIQUID CHROMATOGRAPHY/ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMETRY METHOD FOR THE QUANTIFICATION OF LATANOPROST FREE ACID IN RABBIT AQUEOUS HUMOR AND CILIARY BODY

SALETTI, Rosaria;FOTI, Salvatore
2011-01-01

Abstract

A rapid, selective and sensitive method for quantification of latanoprost free acid in rabbit aqueous humor (AH) and ciliary body (CB) using reverse phase-high performance liquid chromatography coupled with electrospray ionization (ESI)-mass spectrometry/mass spectrometry has been developed and validated. Quantification in AH and CB was achieved by stable isotope dilution employing tetra-deuterated analog of latanoprost free acid, used as internal standard. Sample preparation was based on protein precipitation with methanol in AH, and on liquid extraction with a mixture of ethyl acetate and isopropanol 60:40 (v/v) in CB. Elution was achieved on an octylsilica (C8) column, using an isocratic elution method. Detection was performed on a triple quadrupole mass spectrometer, using ESI in positive ion selected reaction monitoring mode. Calibration curves were linear in the validated concentration ranges of 10-160 ng/mL in AH and 80-1280 ng/g in CB. The accuracy and precision values, obtained from three different sets of quality control samples, each analyzed in triplicate on three different days, were within the generally accepted criteria for analytical methods (< 15%). The limit of detection was 30.66 pg/mL in AH and 237.75 pg/g in CB. The assay proved to be accurate and precise when applied to the in vivo study of latanoprost free acid in rabbit AH and CB after single administration of an eye drops containing latanoprost.
2011
latanoprost free acid; quantitative determination; rabbit aqueous humor; rabbit ciliary body; RP-HPLC/ESI-MS/MS
File in questo prodotto:
File Dimensione Formato  
Quantification Latanoprost.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Dimensione 295.73 kB
Formato Adobe PDF
295.73 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/51263
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact