Abstract Objectives The aim of this study was to compare the outcomes of surgery for impaction of mandibular third molars performed with piezoelectric or high-speed rotatory osteotomy technique. Materials and methods One hundred fifty patients with impacted mandibular third molars were included in the study. Seventy-five were treated with a piezoelectric osteotomy technique (group A) and 75 patients were treated with high-speed rotatory osteotomy (group B). The treatment protocol was the same for both groups. Twenty-four hours after surgery, facial swelling and trismus were evaluated in both groups. Results Mean procedure duration was 22.65 minutes in group A and 17.56 minutes in group B. Mean facial swelling was 4.44 mm in group A and 6.67 mm in group B; trismus was 12.28 mm in group A and 17.28 mm in group B. Statistical analysis revealed significant reductions (p < 0.001) in postoperative facial swelling and trismus in group A, but the duration of the surgical procedure in this group was also significantly increased (p < 0.001 vs group A). Conclusions Compared with high-speed rotatory osteotomy, piezoelectric osteotomy produces less facial swelling and trismus 24 hours after surgery, but it also increases the duration of surgery.

Obiettivi Scopo del lavoro è confrontare le sequele postoperatorie dopo chirurgia di terzi molari inferiori inclusi, trattati con tecnica osteotomica piezoelettrica o rotante ad alta velocità. Materiali e metodi Nello studio sono stati inclusi 150 pazienti con terzi molari inferiori inclusi: 75 pazienti sono stati trattati con tecnica osteotomica piezoelettrica (gruppo A) e 75 pazienti, invece, mediante tecnica osteotomica rotante ad alta velocità (gruppo B). Lo stesso protocollo terapeutico è stato applicato a entrambi i gruppi. Ventiquattro ore dopo l’intervento chirurgico, sono stati valutati in entrambi gruppi due parametri diversi, la tumefazione facciale e il serramento. Risultati Il tempo chirurgico medio è stato di 22,65 minuti nel gruppo A e di 17,56 minuti nel gruppo B; in media la tumefazione facciale è stata di 4,44 mm nel gruppo A e di 6,67 mm nel gruppo B; sono stati rilevati valori medi di serramento di 12,28 mm nel gruppo A e di 17,28 mm nel gruppo B. L’analisi statistica ha mostrato una riduzione significativa (p < 0,001) sia della tumefazione sia del serramento postoperatori nel gruppo A; tuttavia in questo gruppo un aumento statisticamente significativo (p < 0,001) è stato riscontrato nella durata dell’intervento chirurgico. Conclusioni La tecnica osteotomica piezoelettrica ha prodotto tumefazione e serramento minori nel postoperatorio della chirurgia di terzi molari inferiori inclusi, ma ha richiesto un tempo maggiore d’intervento, se confrontata con la tecnica osteotomica rotante ad alta velocità.

Tecnica osteotomica piezoelettrica e rotante nella chirurgia dei terzi molari inferiori inclusi: comparazione delle sequele postoperatorie

PEDULLA', EUGENIO;RAPISARDA, Ernesto
2011-01-01

Abstract

Abstract Objectives The aim of this study was to compare the outcomes of surgery for impaction of mandibular third molars performed with piezoelectric or high-speed rotatory osteotomy technique. Materials and methods One hundred fifty patients with impacted mandibular third molars were included in the study. Seventy-five were treated with a piezoelectric osteotomy technique (group A) and 75 patients were treated with high-speed rotatory osteotomy (group B). The treatment protocol was the same for both groups. Twenty-four hours after surgery, facial swelling and trismus were evaluated in both groups. Results Mean procedure duration was 22.65 minutes in group A and 17.56 minutes in group B. Mean facial swelling was 4.44 mm in group A and 6.67 mm in group B; trismus was 12.28 mm in group A and 17.28 mm in group B. Statistical analysis revealed significant reductions (p < 0.001) in postoperative facial swelling and trismus in group A, but the duration of the surgical procedure in this group was also significantly increased (p < 0.001 vs group A). Conclusions Compared with high-speed rotatory osteotomy, piezoelectric osteotomy produces less facial swelling and trismus 24 hours after surgery, but it also increases the duration of surgery.
2011
Obiettivi Scopo del lavoro è confrontare le sequele postoperatorie dopo chirurgia di terzi molari inferiori inclusi, trattati con tecnica osteotomica piezoelettrica o rotante ad alta velocità. Materiali e metodi Nello studio sono stati inclusi 150 pazienti con terzi molari inferiori inclusi: 75 pazienti sono stati trattati con tecnica osteotomica piezoelettrica (gruppo A) e 75 pazienti, invece, mediante tecnica osteotomica rotante ad alta velocità (gruppo B). Lo stesso protocollo terapeutico è stato applicato a entrambi i gruppi. Ventiquattro ore dopo l’intervento chirurgico, sono stati valutati in entrambi gruppi due parametri diversi, la tumefazione facciale e il serramento. Risultati Il tempo chirurgico medio è stato di 22,65 minuti nel gruppo A e di 17,56 minuti nel gruppo B; in media la tumefazione facciale è stata di 4,44 mm nel gruppo A e di 6,67 mm nel gruppo B; sono stati rilevati valori medi di serramento di 12,28 mm nel gruppo A e di 17,28 mm nel gruppo B. L’analisi statistica ha mostrato una riduzione significativa (p < 0,001) sia della tumefazione sia del serramento postoperatori nel gruppo A; tuttavia in questo gruppo un aumento statisticamente significativo (p < 0,001) è stato riscontrato nella durata dell’intervento chirurgico. Conclusioni La tecnica osteotomica piezoelettrica ha prodotto tumefazione e serramento minori nel postoperatorio della chirurgia di terzi molari inferiori inclusi, ma ha richiesto un tempo maggiore d’intervento, se confrontata con la tecnica osteotomica rotante ad alta velocità.
third molar surgery; swelling; piezosurgery; serramento; tumefazione; chirurgia piezoelettrica
File in questo prodotto:
File Dimensione Formato  
Tecnica osteotomica piezoelettrica e rotante nella chirurgia dei terzi molari inferiori inclusi- comparazione delle sequele postoperatorie.pdf

solo gestori archivio

Licenza: Non specificato
Dimensione 413.98 kB
Formato Adobe PDF
413.98 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/61826
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact