In civil buildings, large part of energy consumption of common service is related to lift apparatus operations. Considering the huge diffusion of roped elevators and their reciprocating operating mode, a critical evaluation of energy streams has been done using an accurate model specially developed. Thus, a retrofit kit has been studied and designed able to store the energy during the generating mode of the electrical machine and to recover it back in motor operation. Finally, a comprehensive evaluation of the saved energy parameterized with the numbers of passengers and lift duty cycle is presented, as well as the kit cost estimation and pay-back time.

Energy harvesting in roped elevators

CACCIATO, MARIO;RACITI, Angelo;SCARCELLA, Giuseppe;SCELBA, GIACOMO
2014-01-01

Abstract

In civil buildings, large part of energy consumption of common service is related to lift apparatus operations. Considering the huge diffusion of roped elevators and their reciprocating operating mode, a critical evaluation of energy streams has been done using an accurate model specially developed. Thus, a retrofit kit has been studied and designed able to store the energy during the generating mode of the electrical machine and to recover it back in motor operation. Finally, a comprehensive evaluation of the saved energy parameterized with the numbers of passengers and lift duty cycle is presented, as well as the kit cost estimation and pay-back time.
2014
978-147994749-2
File in questo prodotto:
File Dimensione Formato  
Speedam14_1.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Dimensione 1.11 MB
Formato Adobe PDF
1.11 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/70586
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 6
social impact