Evaporative cooling is often the only device used in farrowing houses in areas with hot dry climate. The system dimensioning, especially for extremely hot summer conditions, needs a deep hygro-thermal analysis of the indoor climate. During summer 2001 an experimental trial was carried out in a farrowing house, provided with an evaporative cooling pad system, of a farm leader in intensive swine breeding in Eastern Sicily. The data analysis showed that the microclimatic conditions inside the house are not always within the limits of some heat stress indexes.In this paper a model, based on air psycrometric relations and sensible and latent heat balances, simulates the effectiveness of the evaporative cooling system in dependence on the external climatic conditions, the ventilation rate and the number of animals.The results are presented as diagrams that, by relating indoor and outdoor hygro-thermal variables with ventilation, could be a useful tool to improve the system management and to support system design for the same typology of buildings.

Analisi e simulazione delle condizioni di benessere termo-igrometrico in sale parto di porcilaia con raffrescamento evaporativo

ARCIDIACONO, Claudia
2006-01-01

Abstract

Evaporative cooling is often the only device used in farrowing houses in areas with hot dry climate. The system dimensioning, especially for extremely hot summer conditions, needs a deep hygro-thermal analysis of the indoor climate. During summer 2001 an experimental trial was carried out in a farrowing house, provided with an evaporative cooling pad system, of a farm leader in intensive swine breeding in Eastern Sicily. The data analysis showed that the microclimatic conditions inside the house are not always within the limits of some heat stress indexes.In this paper a model, based on air psycrometric relations and sensible and latent heat balances, simulates the effectiveness of the evaporative cooling system in dependence on the external climatic conditions, the ventilation rate and the number of animals.The results are presented as diagrams that, by relating indoor and outdoor hygro-thermal variables with ventilation, could be a useful tool to improve the system management and to support system design for the same typology of buildings.
2006
SOW; SENSIBLE AND LATENT HEAT; MATHEMATICAL MODEL
File in questo prodotto:
File Dimensione Formato  
porcilaia_tot.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: Non specificato
Dimensione 6.01 MB
Formato Adobe PDF
6.01 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/8985
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact