Large-area PhotoMultiplier Tubes ( pmt ) allow to efficiently instrument Liquid Scintil- lator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos’ extremely elusive nature. Depending on the detector light yield, several scintillation photons stem- ming from the same neutrino interaction are likely to hit a single pmt in a few tens/hundreds of nanoseconds, resulting in several photoelectrons ( pe s) to pile-up at the pmt anode. In such scenario, the signal generated by each pe is entangled to the others, and an accurate pmt charge reconstruction becomes challenging. This manuscript describes an experimental method able to address the pmt charge reconstruction in the case of large pe pile-up, providing an unbiased charge estimator at the permille level up to 15 detected pe s. The method is based on a signal filtering technique (Wiener filter) which suppresses the noise due to both pmt and readout electronics, and on a Fourier-based deconvolution able to minimize the influence of signal distortions — such as an overshoot. The analysis of simulated pmt waveforms shows that the slope of a linear regression modeling the relation between reconstructed and true charge values improves from 0 . 769 ± 0 . 001 (without deconvolution) to 0 . 989 ± 0 . 001 (with deconvolution), where unitary slope implies perfect reconstruction. A C++ implementation of the charge reconstruction algorithm is available online at [1].

Charge reconstruction in large-area photomultipliers

GRASSI, MARIA ELENA;M. Buscemi;R. Caruso;A. Fabbri;A. Insolia;Lo Presti D;NASTASI, ANNA ELISA MARIA;SAGGESE, Paolo;
2018-01-01

Abstract

Large-area PhotoMultiplier Tubes ( pmt ) allow to efficiently instrument Liquid Scintil- lator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos’ extremely elusive nature. Depending on the detector light yield, several scintillation photons stem- ming from the same neutrino interaction are likely to hit a single pmt in a few tens/hundreds of nanoseconds, resulting in several photoelectrons ( pe s) to pile-up at the pmt anode. In such scenario, the signal generated by each pe is entangled to the others, and an accurate pmt charge reconstruction becomes challenging. This manuscript describes an experimental method able to address the pmt charge reconstruction in the case of large pe pile-up, providing an unbiased charge estimator at the permille level up to 15 detected pe s. The method is based on a signal filtering technique (Wiener filter) which suppresses the noise due to both pmt and readout electronics, and on a Fourier-based deconvolution able to minimize the influence of signal distortions — such as an overshoot. The analysis of simulated pmt waveforms shows that the slope of a linear regression modeling the relation between reconstructed and true charge values improves from 0 . 769 ± 0 . 001 (without deconvolution) to 0 . 989 ± 0 . 001 (with deconvolution), where unitary slope implies perfect reconstruction. A C++ implementation of the charge reconstruction algorithm is available online at [1].
2018
Calorimeter methods; Liquid detectors; Photon detectors for UV, visible and IR photons (vacuum) (photomultipliers, HPDs, others); Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators)
File in questo prodotto:
File Dimensione Formato  
Grassi_2018_J._Inst._13_P02008.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Dimensione 1.89 MB
Formato Adobe PDF
1.89 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/317087
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact