In the framework of the ongoing EU-funded innovation project called e-SAFE (energy and Seismic Affordable rEnovation solutions), several solutions for the energy and seismic deep renovation of reinforced-concrete (RC) framed buildings in the EU countries are going to be developed and demonstrated. One of these solutions makes use of cross laminated timber (CLT) panels connected to the existing RC frame through specifically designed dampers to increase the seismic and energy performances of the existing envelope. This paper aims to preliminary assess the hygrothermal performance of such CLT panels when applied to various typical wall structures under different climate conditions in Italy through numerical simulations carried out according to the EN 13788 Standard and considering various indoor vapor production classes. Results show that the most problematic existing wall structures are uninsulated concrete walls, for which a risk of surface condensation and mold growth is predicted in all climate zones because of their low thermal resistance (U-value of 3.55 W·m-2·K-1), followed by uninsulated solid brick walls (U-value of 1.81 W·m-2·K-1). The application of CLT panels is found to not only significantly improve the thermal behaviour of the walls, but also to eliminate any surface and interstitial condensation issues in all climate zones.

Hygrothermal Analysis of CLT-Based Retrofit Strategy of Existing Wall Assemblies According to EN 13788 Standard

Costanzo, Vincenzo;Evola, Gianpiero;Gagliano, Antonio;Marletta, Luigi;Nocera, Francesco
Membro del Collaboration Group
2021-01-01

Abstract

In the framework of the ongoing EU-funded innovation project called e-SAFE (energy and Seismic Affordable rEnovation solutions), several solutions for the energy and seismic deep renovation of reinforced-concrete (RC) framed buildings in the EU countries are going to be developed and demonstrated. One of these solutions makes use of cross laminated timber (CLT) panels connected to the existing RC frame through specifically designed dampers to increase the seismic and energy performances of the existing envelope. This paper aims to preliminary assess the hygrothermal performance of such CLT panels when applied to various typical wall structures under different climate conditions in Italy through numerical simulations carried out according to the EN 13788 Standard and considering various indoor vapor production classes. Results show that the most problematic existing wall structures are uninsulated concrete walls, for which a risk of surface condensation and mold growth is predicted in all climate zones because of their low thermal resistance (U-value of 3.55 W·m-2·K-1), followed by uninsulated solid brick walls (U-value of 1.81 W·m-2·K-1). The application of CLT panels is found to not only significantly improve the thermal behaviour of the walls, but also to eliminate any surface and interstitial condensation issues in all climate zones.
2021
CLT panels, EN 13788 Standard, hygrothermal analysis, walls retrofit solutions
File in questo prodotto:
File Dimensione Formato  
65.2-4_28.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: DRM non definito
Dimensione 529.27 kB
Formato Adobe PDF
529.27 kB Adobe PDF Visualizza/Apri