These searches in vitro on dental materials used in Rehabilitative Dentistry has realized to evaluate mechanical properties of composite resins, enamel-dentin adhesives, and endodontic cements with different thickness light cured by two different lamps: a halogen lamp of new generation (Astralis 10 Ivoclar Vivadent) and a LED lamp (MiniLED Satelec), used in continuous modality to high intensity of power ( > 1000 mW/cm2) for exposure times of 10 and 20 seconds. On samples of special geometry realized on mechanical tests of Vickers hardness, compressive strength, flexural strength, wear and wear after acid treatments (ortophosphoric acid to 36%, hydrogen peroxide 10%, hydrogen peroxide to 20%, potassium permanganate to 10%, sodium ethoxide 10%) have been made on samples with suitable shapes. The statistical analysis on the degree of roughness measured on the post surface was performed by means of the two-way ANOVA test; the level of significance was set at 0,05 (P < 0,05). Moreover, it has been possible to define optimal operative conditions in terms of exposure time, sample thickness, in order to obtain homogeneously cured dental materials. The results have shown that the halogen source used in this research allows to reach greater conversion degrees in a shorter time than the LED one. Vickers hardness scores both in the upper surface, directly exposed to light source, and in the lower surface, allowed to evaluate degree of polymerization of any sample according to different time and modality. The values of compression have shown that at the same time of exposure and of release modality of light, the light source used changes the compressive strength of dental materials analyzed. The dental materials containing hybrid and micro hybrid components tested answered better to action of halogen light. The nano ceramic component results more strength to compression if it is cured with LED source. Using a LED lamp has been shown that is useful not increase for each increments the 2 mm of thickness and extend the times of photo polymerization, in way to improve the mechanical characteristics of dental materials, above all it is necessary to photo curing to the distance and to work on dysfunctional patients, having to rehabilitate areas subjected to great stresses. The flexural values observed among dental materials tested have revealed that the halogen source, used for the same times and with the same modality, guarantee greater values to flexural strength than the LED one. The complete polymerization of tested materials, indicated by strength flexural values depends more from thickness of materials that by times of radiation. The wear values and wear after treatments with acids ((ortophosphoric acid to 36%, hydrogen peroxide 10%, hydrogen peroxide to 20%, potassium permanganate to 10%, sodium ethoxide 10%) observed among dental materials tested have revealed that the LED source, used for the same times and the same modalities, guarantees greater wear strength values than the halogen source. So, it has been observed that dental materials behave in different ways probably depending on the composition of their basis.

Le ricerche in vitro sui materiali dentari utilizzati nell Odontoiatria Riabilitativa sono state realizzate al fine di valutare le proprietà meccaniche di resine composite, adesivi smalto-dentinali e cementi endodontici di diverso spessore foto polimerizzati con due differenti lampade: un alogena di nuova generazione (Astralis 10 Ivoclar Vivadent) e una lampada LED (MiniLED Satelec), adoperate in modalità continua ad alta intensità di potenza ( > 1000 mW/cm2) e in modalità incrementale per tempi di esposizione di 10 e 20 secondi. Su campioni di opportuna geometria sono stati eseguiti test meccanici di compressione, flessione, durezza Vickers, usura e usura dopo trattamenti con acidi (acido orto fosforico al 36%, perossido di idrogeno al 10%, perossido di idrogeno al 20%, permanganato di potassio al 10%, etossido di sodio al 10%), e analisi al microscopio elettronico a scansione (SEM). L analisi statistica è stata effettuata utilizzando il test ANOVA a effetti fissi a due vie per campioni dipendenti (P < 0,05). I risultati delle prove hanno indicato che la sorgente alogena utilizzata nella sperimentazione permette di raggiungere gradi di conversione maggiori e in tempi più brevi rispetto a quella LED. È stato inoltre possibile definire le condizioni operative ottimali, in termini di tempo d esposizione e di spessore del campione, per ottenere materiali reticolati omogeneamente. I valori di durezza Vickers sia della superficie superiore, direttamente esposta alla fonte di luce, sia di quella inferiore hanno permesso di valutare il grado di polimerizzazione dei campioni irradiati per tempi e con modalità differenti. I valori di compressione hanno dimostrato che a parità di tempo di esposizione e di modalità di rilascio della luce, la sorgente luminosa adoperata influenza la resistenza a compressione dei materiali dentari analizzati. I materiali dentari contenenti componenti ibride e microibride testati rispondono meglio all azione della luce alogena. La componente nano ceramica risulta più resistente alla compressione se polimerizzata con sorgente LED. Utilizzando una lampada LED si è dimostrato che è consigliabile non superare per ogni apporto i 2 mm di spessore e prolungare i tempi di foto polimerizzazione, in modo da migliorare le caratteristiche meccaniche dei materiali dentari, specie quando è necessario foto polimerizzare a distanza e si opera su pazienti disfunzionali, dovendo riabilitare aree sottoposte a notevoli stress. I valori di flessione osservati tra i materiali dentari testati hanno rivelato che la sorgente alogena, utilizzata per identici tempi e con uguale modalità, garantiscono maggiori valori di resistenza a flessione rispetto alla LED. La completa polimerizzazione dei materiali testati, indicata dai valori di resistenza a flessione dipende comunque più dallo spessore dei materiali che dai tempi di irraggiamento.I valori di usura e usura dopo trattamenti con acidi (acido orto fosforico al 36%, perossido di idrogeno al 10%, perossido di idrogeno al 20%, permanganato di potassio al 10%, etossido di sodio al 10%) osservati tra i materiali dentari testati hanno rivelato che la sorgente LED, utilizzata per identici tempi e con uguale modalità, garantisce maggiori valori di resistenza a usura rispetto alla sorgente alogena. È stato così osservato che i materiali dentari esaminati presentano comportamenti alquanto differenti legati presumibilmente alla loro composizione di base.

RICERCHE IN VITRO SUI MATERIALI DENTARI NELLA ODONTOIATRIA RIABILITATIVA IN PAZIENTI SOTTOPOSTI A TERAPIA ORTOGNATODONTICA / Casella, Giuseppina. - (2011 Dec 06).

RICERCHE IN VITRO SUI MATERIALI DENTARI NELLA ODONTOIATRIA RIABILITATIVA IN PAZIENTI SOTTOPOSTI A TERAPIA ORTOGNATODONTICA

CASELLA, GIUSEPPINA
2011-12-06

Abstract

These searches in vitro on dental materials used in Rehabilitative Dentistry has realized to evaluate mechanical properties of composite resins, enamel-dentin adhesives, and endodontic cements with different thickness light cured by two different lamps: a halogen lamp of new generation (Astralis 10 Ivoclar Vivadent) and a LED lamp (MiniLED Satelec), used in continuous modality to high intensity of power ( > 1000 mW/cm2) for exposure times of 10 and 20 seconds. On samples of special geometry realized on mechanical tests of Vickers hardness, compressive strength, flexural strength, wear and wear after acid treatments (ortophosphoric acid to 36%, hydrogen peroxide 10%, hydrogen peroxide to 20%, potassium permanganate to 10%, sodium ethoxide 10%) have been made on samples with suitable shapes. The statistical analysis on the degree of roughness measured on the post surface was performed by means of the two-way ANOVA test; the level of significance was set at 0,05 (P < 0,05). Moreover, it has been possible to define optimal operative conditions in terms of exposure time, sample thickness, in order to obtain homogeneously cured dental materials. The results have shown that the halogen source used in this research allows to reach greater conversion degrees in a shorter time than the LED one. Vickers hardness scores both in the upper surface, directly exposed to light source, and in the lower surface, allowed to evaluate degree of polymerization of any sample according to different time and modality. The values of compression have shown that at the same time of exposure and of release modality of light, the light source used changes the compressive strength of dental materials analyzed. The dental materials containing hybrid and micro hybrid components tested answered better to action of halogen light. The nano ceramic component results more strength to compression if it is cured with LED source. Using a LED lamp has been shown that is useful not increase for each increments the 2 mm of thickness and extend the times of photo polymerization, in way to improve the mechanical characteristics of dental materials, above all it is necessary to photo curing to the distance and to work on dysfunctional patients, having to rehabilitate areas subjected to great stresses. The flexural values observed among dental materials tested have revealed that the halogen source, used for the same times and with the same modality, guarantee greater values to flexural strength than the LED one. The complete polymerization of tested materials, indicated by strength flexural values depends more from thickness of materials that by times of radiation. The wear values and wear after treatments with acids ((ortophosphoric acid to 36%, hydrogen peroxide 10%, hydrogen peroxide to 20%, potassium permanganate to 10%, sodium ethoxide 10%) observed among dental materials tested have revealed that the LED source, used for the same times and the same modalities, guarantees greater wear strength values than the halogen source. So, it has been observed that dental materials behave in different ways probably depending on the composition of their basis.
6-dic-2011
Le ricerche in vitro sui materiali dentari utilizzati nell Odontoiatria Riabilitativa sono state realizzate al fine di valutare le proprietà meccaniche di resine composite, adesivi smalto-dentinali e cementi endodontici di diverso spessore foto polimerizzati con due differenti lampade: un alogena di nuova generazione (Astralis 10 Ivoclar Vivadent) e una lampada LED (MiniLED Satelec), adoperate in modalità continua ad alta intensità di potenza ( &gt; 1000 mW/cm2) e in modalità incrementale per tempi di esposizione di 10 e 20 secondi. Su campioni di opportuna geometria sono stati eseguiti test meccanici di compressione, flessione, durezza Vickers, usura e usura dopo trattamenti con acidi (acido orto fosforico al 36%, perossido di idrogeno al 10%, perossido di idrogeno al 20%, permanganato di potassio al 10%, etossido di sodio al 10%), e analisi al microscopio elettronico a scansione (SEM). L analisi statistica è stata effettuata utilizzando il test ANOVA a effetti fissi a due vie per campioni dipendenti (P &lt; 0,05). I risultati delle prove hanno indicato che la sorgente alogena utilizzata nella sperimentazione permette di raggiungere gradi di conversione maggiori e in tempi più brevi rispetto a quella LED. È stato inoltre possibile definire le condizioni operative ottimali, in termini di tempo d esposizione e di spessore del campione, per ottenere materiali reticolati omogeneamente. I valori di durezza Vickers sia della superficie superiore, direttamente esposta alla fonte di luce, sia di quella inferiore hanno permesso di valutare il grado di polimerizzazione dei campioni irradiati per tempi e con modalità differenti. I valori di compressione hanno dimostrato che a parità di tempo di esposizione e di modalità di rilascio della luce, la sorgente luminosa adoperata influenza la resistenza a compressione dei materiali dentari analizzati. I materiali dentari contenenti componenti ibride e microibride testati rispondono meglio all azione della luce alogena. La componente nano ceramica risulta più resistente alla compressione se polimerizzata con sorgente LED. Utilizzando una lampada LED si è dimostrato che è consigliabile non superare per ogni apporto i 2 mm di spessore e prolungare i tempi di foto polimerizzazione, in modo da migliorare le caratteristiche meccaniche dei materiali dentari, specie quando è necessario foto polimerizzare a distanza e si opera su pazienti disfunzionali, dovendo riabilitare aree sottoposte a notevoli stress. I valori di flessione osservati tra i materiali dentari testati hanno rivelato che la sorgente alogena, utilizzata per identici tempi e con uguale modalità, garantiscono maggiori valori di resistenza a flessione rispetto alla LED. La completa polimerizzazione dei materiali testati, indicata dai valori di resistenza a flessione dipende comunque più dallo spessore dei materiali che dai tempi di irraggiamento.I valori di usura e usura dopo trattamenti con acidi (acido orto fosforico al 36%, perossido di idrogeno al 10%, perossido di idrogeno al 20%, permanganato di potassio al 10%, etossido di sodio al 10%) osservati tra i materiali dentari testati hanno rivelato che la sorgente LED, utilizzata per identici tempi e con uguale modalità, garantisce maggiori valori di resistenza a usura rispetto alla sorgente alogena. È stato così osservato che i materiali dentari esaminati presentano comportamenti alquanto differenti legati presumibilmente alla loro composizione di base.
Dental Materials, polymerization, halogen lamp, LED lamp, degree of conversion
RICERCHE IN VITRO SUI MATERIALI DENTARI NELLA ODONTOIATRIA RIABILITATIVA IN PAZIENTI SOTTOPOSTI A TERAPIA ORTOGNATODONTICA / Casella, Giuseppina. - (2011 Dec 06).
File in questo prodotto:
File Dimensione Formato  
Tesi Giuseppina Casella.pdf

accesso aperto

Tipologia: Tesi di dottorato
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 730.13 kB
Formato Adobe PDF
730.13 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/585971
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact