An open winding approach can lead to substantial performance improvement on grid-connected induction motors, which are still largely used for constant speed applications. Exploiting an open-end winding configuration to manage bidirectional power flows, the proposed configuration is less expensive than a conventional variable frequency induction motor drive, since a bidirectional controlled rectifier is not required, neither grid-side filters. In constant speed applications the proposed approach not only is able to maximize the average motor efficiency, but also to improve the power factor, limiting the start-up current and compensating the effects of voltage sags. Moreover, an energy storage system can be straightforwardly introduced in the system, enabling load peak shaving and load shifting operations. The proposed approach is first theoretical introduced and analyzed, then a performance assessment is accomplished by simulations.

Grid-Connected Open-end Winding Induction Motor Drives

Testa A;Tornello LD;Scelba G;Scarcella G
2020-01-01

Abstract

An open winding approach can lead to substantial performance improvement on grid-connected induction motors, which are still largely used for constant speed applications. Exploiting an open-end winding configuration to manage bidirectional power flows, the proposed configuration is less expensive than a conventional variable frequency induction motor drive, since a bidirectional controlled rectifier is not required, neither grid-side filters. In constant speed applications the proposed approach not only is able to maximize the average motor efficiency, but also to improve the power factor, limiting the start-up current and compensating the effects of voltage sags. Moreover, an energy storage system can be straightforwardly introduced in the system, enabling load peak shaving and load shifting operations. The proposed approach is first theoretical introduced and analyzed, then a performance assessment is accomplished by simulations.
2020
Reactive power
Stators
Induction motors
Inverters
Surges
Windings
Torque
Induction motor
open winding
energy saving
grid connected motor
power factor
inrush current
File in questo prodotto:
File Dimensione Formato  
Grid-Connected_Open-end_Winding_Induction_Motor_Drives.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 498.47 kB
Formato Adobe PDF
498.47 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/647149
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 3
social impact