The paper presents an effective method for the measurement, using a standard infrared camera working at 25 Hz frame rate with 320256 pixels full frame, of very fast temperature transients (i.e., having a bandwidth of 10 kHz or more) which, in principle, would require a much faster acquisition rate. The proposed method is based on triggering multiple time-delayed acquisitions (MTDA) of the observed thermal phenomenon, which has to be reproducible, by means of a very precise and stable programmable digital micro-controller and by reconstructing the time domain IR sequence using the frames acquired at each trigger event. The method could find application in assessing the reliability of power electronic devices and, in particular, to measure dynamically temperature distribution over the source metal of Power MOSFETs or IGBTs, which feature very fast thermal transients, even in the hundreds of microsecond scale and might develop local hot spots as a consequence of aging or failures.

Temporal resampling of time-varying infrared images sequences

SCIMONE, Tommaso;TESTA, Antonio
2014-01-01

Abstract

The paper presents an effective method for the measurement, using a standard infrared camera working at 25 Hz frame rate with 320256 pixels full frame, of very fast temperature transients (i.e., having a bandwidth of 10 kHz or more) which, in principle, would require a much faster acquisition rate. The proposed method is based on triggering multiple time-delayed acquisitions (MTDA) of the observed thermal phenomenon, which has to be reproducible, by means of a very precise and stable programmable digital micro-controller and by reconstructing the time domain IR sequence using the frames acquired at each trigger event. The method could find application in assessing the reliability of power electronic devices and, in particular, to measure dynamically temperature distribution over the source metal of Power MOSFETs or IGBTs, which feature very fast thermal transients, even in the hundreds of microsecond scale and might develop local hot spots as a consequence of aging or failures.
2014
0000000000
Infrared camera
equivalent sampling frequency
power electronics devices
File in questo prodotto:
File Dimensione Formato  
QIRT-2014-082.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 776.85 kB
Formato Adobe PDF
776.85 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/647949
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact