FLASH radiotherapy (FLASH-RT) is a novel technique that employs Ultra-High Dose Rate (UHDR) beams (> 40 Gy/s) and total irradiation times < 200 ms, significantly different from conventional radiotherapy (CONV-RT, ∼ Gy/min, ∼ minutes). Its main advantage is an enhanced sparing of normal tissues without compromising tumor control with respect to CONV-RT. However, FLASH-RT clinical translation remains limited by several challenges. In dosimetry, under UHDR conditions, ionization chambers-the gold standard in CONVRT-experience significant ion recombination, thus motivating the investigation of alternative dosimeters. Recently, a portable graphite calorimeter realized by the NPL (UK) and thermoluminescence dosimeters (LiF:Mg,Ti and CaF2 : Mn) were characterized by the INFN-CT and University of Catania research groups using UHDR electron beams at the Centro Pisano for FLASH Radiotherapy (CPFR, Pisa). Their response was compared with the one obtained with the reference FlashDiamond (PTW) detector. Both dosimeters showed dose rate independence up to ∼ 9 · 10^5 Gy/s, supporting their reliability for dose measurements under UHDR conditions.

Dosimetric characterization of a graphite calorimeter and TLDs for FLASH radiotherapy

Arcidiacono Giorgia
Primo
;
Gueli Anna Maria;Stella Giuseppe;
2026-01-01

Abstract

FLASH radiotherapy (FLASH-RT) is a novel technique that employs Ultra-High Dose Rate (UHDR) beams (> 40 Gy/s) and total irradiation times < 200 ms, significantly different from conventional radiotherapy (CONV-RT, ∼ Gy/min, ∼ minutes). Its main advantage is an enhanced sparing of normal tissues without compromising tumor control with respect to CONV-RT. However, FLASH-RT clinical translation remains limited by several challenges. In dosimetry, under UHDR conditions, ionization chambers-the gold standard in CONVRT-experience significant ion recombination, thus motivating the investigation of alternative dosimeters. Recently, a portable graphite calorimeter realized by the NPL (UK) and thermoluminescence dosimeters (LiF:Mg,Ti and CaF2 : Mn) were characterized by the INFN-CT and University of Catania research groups using UHDR electron beams at the Centro Pisano for FLASH Radiotherapy (CPFR, Pisa). Their response was compared with the one obtained with the reference FlashDiamond (PTW) detector. Both dosimeters showed dose rate independence up to ∼ 9 · 10^5 Gy/s, supporting their reliability for dose measurements under UHDR conditions.
2026
978-88-7438-145-6
FLASH radiotherapy, dosimetry, TLDs, calorimetry, UHDR beams
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/733969
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact