In this paper a novel approach to implement a ferrofluid based flow sensor is presented. The device consists of a glass pipe, with an inner diameter of 5 mm and a length of about 180 mm, filled with de-ionized water and a drop of ferro fluid of 0.01 mI. The sensing methodology exploits the influence of the imposed flow rate on the time elapsed between transitions of the ferrofluid mass between two fixed positions. An array of coils is used to monitor the mass movement and to restore the mass in the null position (the center of the retaining coil). The main novelty of the proposed strategy as respect to solutions available in the literature is the exploitation of a Time Domain Readout (TDR) strategy which shows a high robustness against external influences and is compliant with the concept of frequency output sensors. Other advantages of the sensor are high robustness against mechanical shocks, the intrinsic isolation between the electric part and the liquid medium and the low cost of proposed technology.

A time domain readout strategy flow sensor

Ando B.
Primo
;
Baglio S.;Marletta V.
Ultimo
2014-01-01

Abstract

In this paper a novel approach to implement a ferrofluid based flow sensor is presented. The device consists of a glass pipe, with an inner diameter of 5 mm and a length of about 180 mm, filled with de-ionized water and a drop of ferro fluid of 0.01 mI. The sensing methodology exploits the influence of the imposed flow rate on the time elapsed between transitions of the ferrofluid mass between two fixed positions. An array of coils is used to monitor the mass movement and to restore the mass in the null position (the center of the retaining coil). The main novelty of the proposed strategy as respect to solutions available in the literature is the exploitation of a Time Domain Readout (TDR) strategy which shows a high robustness against external influences and is compliant with the concept of frequency output sensors. Other advantages of the sensor are high robustness against mechanical shocks, the intrinsic isolation between the electric part and the liquid medium and the low cost of proposed technology.
2014
978-1-4799-0162-3
Coils; Ferrofluid; Flow sensor; Time domain readout
File in questo prodotto:
File Dimensione Formato  
Baglio_A_Time_Domain_Readout_strategy_flow_sensor.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.07 MB
Formato Adobe PDF
1.07 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/738429
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact