We studied the enzyme glucose oxidase (GOx) immobilization on silicon oxide surfaces. In particular, we optimized the immobilization protocol and verified that it fulfills both requirements of enzyme preservation (measured by enzymatic activity) and VLSI compatibility. The immobilization consists of four steps: oxide activation, silanization, linker molecule deposition and GOx immobilization. It is crucial to form an uniform linker layer on the sample surface in order to maximize the sites available for enzyme bonding and achieving the best enzyme deposition. In this study, utilizing glutaraldehyde as bifunctional reagent, we monitored its uniformity on the surface through X-ray Photoelectron Spectroscopy (XPS). Once optimized, the same protocol was used to anchor the enzyme in a porous silicon dioxide matrix. Gold labeled GOx molecules were monitored by electron diffraction X-ray (EDX) measurements coupled with scanning electron microscopy (SEM). The enzymatic activity was also monitored to confirm the goodness of the proposed immobilization method. Finally, the electrical characterization of MOS capacitors, showing a shift of about 1 V in the flat band voltage, demonstrated the possibility to use this approach for electrical detection.

Glucose oxidase characterization for the fabrication of hybrid microelectronic devices

A. SCANDURRA;SINATRA, Fulvia;RENIS, Marcella;
2007-01-01

Abstract

We studied the enzyme glucose oxidase (GOx) immobilization on silicon oxide surfaces. In particular, we optimized the immobilization protocol and verified that it fulfills both requirements of enzyme preservation (measured by enzymatic activity) and VLSI compatibility. The immobilization consists of four steps: oxide activation, silanization, linker molecule deposition and GOx immobilization. It is crucial to form an uniform linker layer on the sample surface in order to maximize the sites available for enzyme bonding and achieving the best enzyme deposition. In this study, utilizing glutaraldehyde as bifunctional reagent, we monitored its uniformity on the surface through X-ray Photoelectron Spectroscopy (XPS). Once optimized, the same protocol was used to anchor the enzyme in a porous silicon dioxide matrix. Gold labeled GOx molecules were monitored by electron diffraction X-ray (EDX) measurements coupled with scanning electron microscopy (SEM). The enzymatic activity was also monitored to confirm the goodness of the proposed immobilization method. Finally, the electrical characterization of MOS capacitors, showing a shift of about 1 V in the flat band voltage, demonstrated the possibility to use this approach for electrical detection.
2007
glucose oxidase; silicon oxide; biosensors
File in questo prodotto:
File Dimensione Formato  
C 08 Fichera SPIE Canarie 2007.pdf

solo gestori archivio

Tipologia: Documento in Pre-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.82 MB
Formato Adobe PDF
1.82 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/83437
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact