The evaluation of the seismic behaviour of buildings not designed to resist earthquake loading represents a subject of great practical value and of high computation cost. For this reason in the last years many authors have developed simplified methodologies, based on pushover analyses that, with a reduced computational effort if compared with dynamic nonlinear analyses, are able to give a reliable measure of the resistance under earthquake loading. In the paper the seismic resistance of a RC building that has been built in a high seismic area without any seismic provision, is assessed by means of procedures based on pushover and dynamic nonlinear analyses performed on three-dimensional finite element models as well as simplified procedures based on equivalent singledegree- of-freedom systems. The results that have been obtained clearly show the high vulnerability of the structure for which a seismic retrofit is recommended. In a companion paper the seismic resistance of the building after a retrofitting which includes a partial reinforcement of the existing structure and base-isolation is investigated.

Seismic Performance of a Reinforced Concrete building not designed to withstand Earthquake Loading

CALIO', Ivo Domenico;
2005-01-01

Abstract

The evaluation of the seismic behaviour of buildings not designed to resist earthquake loading represents a subject of great practical value and of high computation cost. For this reason in the last years many authors have developed simplified methodologies, based on pushover analyses that, with a reduced computational effort if compared with dynamic nonlinear analyses, are able to give a reliable measure of the resistance under earthquake loading. In the paper the seismic resistance of a RC building that has been built in a high seismic area without any seismic provision, is assessed by means of procedures based on pushover and dynamic nonlinear analyses performed on three-dimensional finite element models as well as simplified procedures based on equivalent singledegree- of-freedom systems. The results that have been obtained clearly show the high vulnerability of the structure for which a seismic retrofit is recommended. In a companion paper the seismic resistance of the building after a retrofitting which includes a partial reinforcement of the existing structure and base-isolation is investigated.
2005
978-1-84564-004-0
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/57737
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact