A large-area monolithic silicon detector telescope for particle identification has recently been realized. Due to the high capacitance (40 nF) of the Delta E stage, commercially available charge preamplifiers cannot be used. We report on the design and characterization of a charge preamplifier suitably developed for the Delta E stage. (C) 1998 Elsevier Science B.V. All rights reserved.
Front-end electronics for a large-area silicon detector telescope
MUSUMARRA, Agatino;TUDISCO, SALVATORE
1998-01-01
Abstract
A large-area monolithic silicon detector telescope for particle identification has recently been realized. Due to the high capacitance (40 nF) of the Delta E stage, commercially available charge preamplifiers cannot be used. We report on the design and characterization of a charge preamplifier suitably developed for the Delta E stage. (C) 1998 Elsevier Science B.V. All rights reserved.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
NIMA-DeGeronimo.pdf
solo gestori archivio
Tipologia:
Versione Editoriale (PDF)
Dimensione
95 kB
Formato
Adobe PDF
|
95 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.