Acute renal failure due to ureter compression after a mesh-plug inguinal repair in a kidney transplant recipient has not been previously reported to our knowledge. A 62-year-old man, who successfully underwent kidney transplantation from a deceased donor 6 years earlier, was admitted for elective repair of a direct inguinal hernia. The patient underwent an open mesh-plug repair of the inguinal hernia with placement of a plug in the preperitoneal space. We did not observe the transplanted ureter and bladder during dissection of the inguinal canal. Immediately after surgery, the patient became anuric, and a graft sonography demonstrated massive hydronephrosis. The serum creatinine level increased rapidly, and the patient underwent an emergency reoperation 8 hours later. During surgery, we did not identify the ureter but, immediately after plug removal, urine output increased progressively. We completed the hernia repair using the standard technique, without plug interposition, and the postoperative course was uneventful with complete resolution of graft dysfunction 3 days later. Furthermore, we reviewed the clinical features of complications related to inguinal hernia surgery. An increased risk of urological complications was reported recently in patients with a previous prosthetic hernia repair undergoing kidney transplantation, mainly due to the mesh adhesion to surrounding structures, making the extraperitoneal dissection during the transplant surgery very challenging. Moreover, older male kidney transplant recipients undergoing an inguinal hernia repair may be at higher risk of graft dysfunction due to inguinal herniation of a transplanted ureter. Mesh-plug inguinal hernia repair is a safe surgical technique, but this unique case suggests that kidney transplant recipients with inguinal hernia may be at higher risk of serious urological complications. Surgeons must be aware of the graft and ureter position before proceeding with hernia repair. A prompt diagnosis with graft sonography and abdominal computed tomography scan and emergency surgery may avoid the need for nephrostomy and may resolve graft dysfunction more rapidly.

First Case Report of Acute Renal Failure After Mesh-Plug Inguinal Hernia Repair in a Kidney Transplant Recipient

VEROUX, Massimiliano
Primo
Writing – Review & Editing
;
CAGLIA', Pietro;PALMUCCI, STEFANO;Giaquinta A;VEROUX, Pierfrancesco
Ultimo
2016-01-01

Abstract

Acute renal failure due to ureter compression after a mesh-plug inguinal repair in a kidney transplant recipient has not been previously reported to our knowledge. A 62-year-old man, who successfully underwent kidney transplantation from a deceased donor 6 years earlier, was admitted for elective repair of a direct inguinal hernia. The patient underwent an open mesh-plug repair of the inguinal hernia with placement of a plug in the preperitoneal space. We did not observe the transplanted ureter and bladder during dissection of the inguinal canal. Immediately after surgery, the patient became anuric, and a graft sonography demonstrated massive hydronephrosis. The serum creatinine level increased rapidly, and the patient underwent an emergency reoperation 8 hours later. During surgery, we did not identify the ureter but, immediately after plug removal, urine output increased progressively. We completed the hernia repair using the standard technique, without plug interposition, and the postoperative course was uneventful with complete resolution of graft dysfunction 3 days later. Furthermore, we reviewed the clinical features of complications related to inguinal hernia surgery. An increased risk of urological complications was reported recently in patients with a previous prosthetic hernia repair undergoing kidney transplantation, mainly due to the mesh adhesion to surrounding structures, making the extraperitoneal dissection during the transplant surgery very challenging. Moreover, older male kidney transplant recipients undergoing an inguinal hernia repair may be at higher risk of graft dysfunction due to inguinal herniation of a transplanted ureter. Mesh-plug inguinal hernia repair is a safe surgical technique, but this unique case suggests that kidney transplant recipients with inguinal hernia may be at higher risk of serious urological complications. Surgeons must be aware of the graft and ureter position before proceeding with hernia repair. A prompt diagnosis with graft sonography and abdominal computed tomography scan and emergency surgery may avoid the need for nephrostomy and may resolve graft dysfunction more rapidly.
File in questo prodotto:
File Dimensione Formato  
2016 First Case Report of Acute Renal Failure After... Medicine Clin. Case Report .pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Non specificato
Dimensione 336.46 kB
Formato Adobe PDF
336.46 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/19486
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact