The ion streams emitted from laser generated plasmas and post-accelerated through a high voltage acceleration path, were monitored by solid state 4H-SiC interdigit detectors in time-of-flight configuration. The plasmas are produced by irradiation of an aluminum target through a ns pulsed laser with 10(10) w/cm(2) intensity and 200 mJ pulse energy. Laser-generated plasma exhibits a mean energy of the order of 100 eV per amu. In order to enhance the ion kinetic energy a post acceleration in the range 1 kV -30 kV was employed. In this paper we studied the correlation of the acquired spectra shape with the post acceleration voltage and with the detector polarization condition. An increase in the spectra intensity was observed and studied with increasing both detector reverse bias and post acceleration voltage. Obtained results demonstrate that interdigit 4H-SiC diodes with millimetric size, show a quite good efficiency for ion detection with energy higher than 5 keV and are very promising devices allowing, thanks to their millimetric size, to carry out detectors array systems for the measurement of the spatial distribution of low energy ions generated by pulsed laser-plasmas. (C) 2016 Elsevier Ltd. All rights reserve

SiC interdigit detectors for post-accelerated ions generated by laser plasma

MUSUMECI, Paolo;CALCAGNO, Lucia
2016-01-01

Abstract

The ion streams emitted from laser generated plasmas and post-accelerated through a high voltage acceleration path, were monitored by solid state 4H-SiC interdigit detectors in time-of-flight configuration. The plasmas are produced by irradiation of an aluminum target through a ns pulsed laser with 10(10) w/cm(2) intensity and 200 mJ pulse energy. Laser-generated plasma exhibits a mean energy of the order of 100 eV per amu. In order to enhance the ion kinetic energy a post acceleration in the range 1 kV -30 kV was employed. In this paper we studied the correlation of the acquired spectra shape with the post acceleration voltage and with the detector polarization condition. An increase in the spectra intensity was observed and studied with increasing both detector reverse bias and post acceleration voltage. Obtained results demonstrate that interdigit 4H-SiC diodes with millimetric size, show a quite good efficiency for ion detection with energy higher than 5 keV and are very promising devices allowing, thanks to their millimetric size, to carry out detectors array systems for the measurement of the spatial distribution of low energy ions generated by pulsed laser-plasmas. (C) 2016 Elsevier Ltd. All rights reserve
File in questo prodotto:
File Dimensione Formato  
SiC interdigit detectors for post-accelerated ions generated by laser.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: Non specificato
Dimensione 833.95 kB
Formato Adobe PDF
833.95 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/19888
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact