A new method for the determination of reliable molecular weight averages (MW) and polydispersity index (MWD) values for polydisperse polymers, directly analyzing their matrix.assisted laser/desorption ionization time- of-flight (MALDI-TOF) mass spectra, is reported. Our success is due to the concerted effect of an off-line procedure of MALDI-TOF spectrum processing that includes: (i) signal smoothing to improve the recorded traces of the spectra up to high m/z values; (ii) a subtraction of the misleading contribution to the signals introduced by the offset used in spectrum recording; (iii) examination of the spectra up to the highest possible m/z value for a better accuracy in estimating the MW values. To illustrate this method, three polymers with a wide polydispersity index, a polydimethylsiloxane, a polymethylmethacrylate, and a bisphenol-A copolyether, have been analyzed. Contrary to the general opinion that MW values can be measured directly by MALDI-TOF only for polymers with a very narrow mass distribution, the data reported here show that our off-line procedure is also able to measure reliable MW values for polydisperse materials.

Novel procedure for molecular weight averages measurement of polydisperse polymers directly from matrix-assisted laser desorption/ionization time-of-flight mass spectra

MINEO, PLACIDO
1996-01-01

Abstract

A new method for the determination of reliable molecular weight averages (MW) and polydispersity index (MWD) values for polydisperse polymers, directly analyzing their matrix.assisted laser/desorption ionization time- of-flight (MALDI-TOF) mass spectra, is reported. Our success is due to the concerted effect of an off-line procedure of MALDI-TOF spectrum processing that includes: (i) signal smoothing to improve the recorded traces of the spectra up to high m/z values; (ii) a subtraction of the misleading contribution to the signals introduced by the offset used in spectrum recording; (iii) examination of the spectra up to the highest possible m/z value for a better accuracy in estimating the MW values. To illustrate this method, three polymers with a wide polydispersity index, a polydimethylsiloxane, a polymethylmethacrylate, and a bisphenol-A copolyether, have been analyzed. Contrary to the general opinion that MW values can be measured directly by MALDI-TOF only for polymers with a very narrow mass distribution, the data reported here show that our off-line procedure is also able to measure reliable MW values for polydisperse materials.
File in questo prodotto:
File Dimensione Formato  
fullpaperRCM96.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.01 MB
Formato Adobe PDF
1.01 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/23371
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 76
  • ???jsp.display-item.citation.isi??? 75
social impact