PURPOSE:The aim of this study was to introduce a new paradigm for keratoconus assessment, the keratoconus index (KI), generated from the ratio of peripheral corneal thickness (PCT) to the thinnest corneal thickness (TCT), and calculated by a computer-assisted procedure after ultrabiomicroscope (UBM) examination. Then we compared KI and the keratoconus severity index (KSI), obtained by videokeratography in patients with different stages of keratoconus.METHODS:We studied 60 eyes with different forms of keratoconus using the TMS-3 autotopographer, provided with a keratoconus screening program (using Smolek-Klyce methods) and the commercial version of the ultrasound biomicroscope (Paradigm UBM Plus Model P45) equipped with a 50-MHz probe, which was provided with our computer-assisted program. The proportion test Z and the correlation coefficient R were applied to the outcomes.RESULTS:The keratoconus severity index, KSI, obtained by color-coded videokeratographic maps, was in the range 95% to 32% (mean 52.22%). By means of UBM examination, we obtained 60 images and found values of TCT 0.278-0.592 mm and PCT 0.475-0.704 mm. Applying the computer-assisted method, we obtained values for KI of 1.112-2.159 (mean 1.428).CONCLUSIONS:KI is correlated as well as KSI with the severity of the keratoconus (R = 0.76, P < 0.0001). It can be used as a similar parameter to measure the evolution of the disease, on the basis of corneal thickness rather than the curvature.
Keratoconus staging: A computer-assisted ultrabiomicroscopic method with videokeratographic analysis
AVITABILE, Teresio;FRANCO, Livio;TORRISI, BENEDETTO;
2004-01-01
Abstract
PURPOSE:The aim of this study was to introduce a new paradigm for keratoconus assessment, the keratoconus index (KI), generated from the ratio of peripheral corneal thickness (PCT) to the thinnest corneal thickness (TCT), and calculated by a computer-assisted procedure after ultrabiomicroscope (UBM) examination. Then we compared KI and the keratoconus severity index (KSI), obtained by videokeratography in patients with different stages of keratoconus.METHODS:We studied 60 eyes with different forms of keratoconus using the TMS-3 autotopographer, provided with a keratoconus screening program (using Smolek-Klyce methods) and the commercial version of the ultrasound biomicroscope (Paradigm UBM Plus Model P45) equipped with a 50-MHz probe, which was provided with our computer-assisted program. The proportion test Z and the correlation coefficient R were applied to the outcomes.RESULTS:The keratoconus severity index, KSI, obtained by color-coded videokeratographic maps, was in the range 95% to 32% (mean 52.22%). By means of UBM examination, we obtained 60 images and found values of TCT 0.278-0.592 mm and PCT 0.475-0.704 mm. Applying the computer-assisted method, we obtained values for KI of 1.112-2.159 (mean 1.428).CONCLUSIONS:KI is correlated as well as KSI with the severity of the keratoconus (R = 0.76, P < 0.0001). It can be used as a similar parameter to measure the evolution of the disease, on the basis of corneal thickness rather than the curvature.File | Dimensione | Formato | |
---|---|---|---|
Cornea M.Franco.pdf
solo gestori archivio
Tipologia:
Versione Editoriale (PDF)
Licenza:
Non specificato
Dimensione
271.13 kB
Formato
Adobe PDF
|
271.13 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.