An experimental investigation has been carried out on the properties of electromagnetic shower detectors, composed of a uniform array of plastic scintillating fibers and lead (50:35 by volume ratio) for photons in the energy range 600-1200 MeV, When the photon's incidence angle to the fiber axis is within +/-2 degrees an energy resolution of sigma(E)/E(%) = 5.12/root E[GeV]+1.71+ has been observed.

Experimental study of high-energy resolution lead scintillating fiber calorimetry in the 600-1200 MeV energy region

BELLINI, Vincenzo
Primo
;
1997-01-01

Abstract

An experimental investigation has been carried out on the properties of electromagnetic shower detectors, composed of a uniform array of plastic scintillating fibers and lead (50:35 by volume ratio) for photons in the energy range 600-1200 MeV, When the photon's incidence angle to the fiber axis is within +/-2 degrees an energy resolution of sigma(E)/E(%) = 5.12/root E[GeV]+1.71+ has been observed.
1997
Calorimetry; Lead; Particle detectors; Phosphors; Photons; Plastic filaments
File in questo prodotto:
File Dimensione Formato  
A37_1997_NIM_Bellini_Spaghetti_1997.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 381.59 kB
Formato Adobe PDF
381.59 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/32906