An experimental investigation has been carried out on the properties of electromagnetic shower detectors, composed of a uniform array of plastic scintillating fibers and lead (50:35 by volume ratio) for photons in the energy range 600-1200 MeV, When the photon's incidence angle to the fiber axis is within +/-2 degrees an energy resolution of sigma(E)/E(%) = 5.12/root E[GeV]+1.71+ has been observed.

Experimental study of high-energy resolution lead scintillating fiber calorimetry in the 600-1200 MeV energy region

BELLINI, Vincenzo;
1997-01-01

Abstract

An experimental investigation has been carried out on the properties of electromagnetic shower detectors, composed of a uniform array of plastic scintillating fibers and lead (50:35 by volume ratio) for photons in the energy range 600-1200 MeV, When the photon's incidence angle to the fiber axis is within +/-2 degrees an energy resolution of sigma(E)/E(%) = 5.12/root E[GeV]+1.71+ has been observed.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/32906
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 18
social impact