In recent years imaging techniques that use radionuclides have become more and more clinically relevant as they can provide functional information for specific anatomical districts. This has also involved nephrology, where radionuclides are used to study patients with different degrees of renal function failure up to terminal uremia. Although chronic kidney disease, and dialysis in particular, may affect the distribution and the elimination of radiopharmaceuticals, to date there are no consistent data on the risks associated with their use in this clinical context. In addition to the lack of data on the safety of radio-exposure in dialysis patients, there is also a shortage of information concerning the risk for healthcare staff involved in conducting the dialysis sessions performed after a nuclear test. This study, performed on 29 uremic patients who underwent hemodialysis immediately after a scintigraphic examination, assessed the extent of radio-contamination of the staff and of hemodialysis devices such as monitor, kits and dialysate. The data collected has been used to quantify the radiological risk in dialysis after the exposure to the most common radionuclides.
Management of hemodialysis patient subject to medical-nuclear investigation
Sessa C.;Zanoli L.;
2020-01-01
Abstract
In recent years imaging techniques that use radionuclides have become more and more clinically relevant as they can provide functional information for specific anatomical districts. This has also involved nephrology, where radionuclides are used to study patients with different degrees of renal function failure up to terminal uremia. Although chronic kidney disease, and dialysis in particular, may affect the distribution and the elimination of radiopharmaceuticals, to date there are no consistent data on the risks associated with their use in this clinical context. In addition to the lack of data on the safety of radio-exposure in dialysis patients, there is also a shortage of information concerning the risk for healthcare staff involved in conducting the dialysis sessions performed after a nuclear test. This study, performed on 29 uremic patients who underwent hemodialysis immediately after a scintigraphic examination, assessed the extent of radio-contamination of the staff and of hemodialysis devices such as monitor, kits and dialysate. The data collected has been used to quantify the radiological risk in dialysis after the exposure to the most common radionuclides.File | Dimensione | Formato | |
---|---|---|---|
114 - 2020 - Management del paziente in emodialisi sottoposto ad indagine medico-nucleare.pdf
solo gestori archivio
Tipologia:
Versione Editoriale (PDF)
Dimensione
1.13 MB
Formato
Adobe PDF
|
1.13 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.