Background Multislice computed tomography (MSCT) has generally been accepted as the most accurate modality fulfilling this purpose with good reproducibility. A major drawback of MSCT consists in the use of contrast dye, which may be unsafe in transcatheter aortic valve implantation (TAVI) patients who frequently are affected by renal failure. We sought to appraise the accuracy of intracardiac echocardiography (ICE) in measurements of structures in the aortic root in patients undergoing TAVI. Methods Aortic annulus and sinus of Valsalva diameters were measured using ICE, performed during standard invasive preprocedural assessment in 30 consecutive patients with severe aortic stenosis referred for TAVI. Multislice computed tomography was performed in all patients afterward, and aortic root measurements were made by an independent radiologist. Results Effective ICE measurements were obtained in all patients, easily and without any complication. Mean aortic annulus diameters were 21.9 +/- 1.8 mm using ICE, 22.0 +/- 1.9 mm using MSCT (3-chamber [3-C] view) and 22.8 +/- 1.8 mm using the mean of long-axis and short-axis (L-ax/S-ax) view MSCT (P = .192, ICE vs 3-C MSCT; P < .001, ICE vs L-ax/S-ax MSCT, respectively). Correlation between ICE and both MSCT measurements was good (r(2) = 0.83, P < .001; r(2) = 0.80, P < .001, respectively). Mean sinus of Valsalva diameters were 32.3 +/- 3.3 mm using ICE and 32.5 +/- 3.1 mm using 3-C MSCT view (P = .141). Even in this case, correlation between ICE and both MSCT measurements was excellent (r(2) = 0.96, P < .001). Conclusions In patients referred for TAVI, measurements of the aortic annulus and the sinus of Valsalva using ICE compare favorably with those made at MSCT. This approach might be a useful and reproducible strategy in patients with severe renal impairment to avoid the administration of contrast dye during MSCT

Accuracy of intracardiac echocardiography for aortic root assessment in patients undergoing transcatheter aortic valve implantation

TAMBURINO, Corrado
2012-01-01

Abstract

Background Multislice computed tomography (MSCT) has generally been accepted as the most accurate modality fulfilling this purpose with good reproducibility. A major drawback of MSCT consists in the use of contrast dye, which may be unsafe in transcatheter aortic valve implantation (TAVI) patients who frequently are affected by renal failure. We sought to appraise the accuracy of intracardiac echocardiography (ICE) in measurements of structures in the aortic root in patients undergoing TAVI. Methods Aortic annulus and sinus of Valsalva diameters were measured using ICE, performed during standard invasive preprocedural assessment in 30 consecutive patients with severe aortic stenosis referred for TAVI. Multislice computed tomography was performed in all patients afterward, and aortic root measurements were made by an independent radiologist. Results Effective ICE measurements were obtained in all patients, easily and without any complication. Mean aortic annulus diameters were 21.9 +/- 1.8 mm using ICE, 22.0 +/- 1.9 mm using MSCT (3-chamber [3-C] view) and 22.8 +/- 1.8 mm using the mean of long-axis and short-axis (L-ax/S-ax) view MSCT (P = .192, ICE vs 3-C MSCT; P < .001, ICE vs L-ax/S-ax MSCT, respectively). Correlation between ICE and both MSCT measurements was good (r(2) = 0.83, P < .001; r(2) = 0.80, P < .001, respectively). Mean sinus of Valsalva diameters were 32.3 +/- 3.3 mm using ICE and 32.5 +/- 3.1 mm using 3-C MSCT view (P = .141). Even in this case, correlation between ICE and both MSCT measurements was excellent (r(2) = 0.96, P < .001). Conclusions In patients referred for TAVI, measurements of the aortic annulus and the sinus of Valsalva using ICE compare favorably with those made at MSCT. This approach might be a useful and reproducible strategy in patients with severe renal impairment to avoid the administration of contrast dye during MSCT
File in questo prodotto:
File Dimensione Formato  
Accuracy of intracardiac echocardiography.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 482.31 kB
Formato Adobe PDF
482.31 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/41701
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 10
social impact