Hysteresis is a common phenomenon in nonlinear systems. Piezoelectric bimorphs show hysteretic behavior when operating as actuators. Tools that produce the characterization of these devices are available; they use high-cost setups that measure deformations with resolutions on the order of nanometers. In this paper, a new low-cost experimental setup that uses coupled infrared detectors to investigate the behavior of piezoelectric actuators is discussed. The tool, providing deformation measurements with a resolution on the order of 10 ìm, is intended to produce a rough estimation of the device behavior and is of interest for research and educational purposes. Low cost, easy reproducibility in research and educational laboratories, a contactless measurement strategy, an inset calibration facility, and a suitable user interface are the main features of the tool developed. Notes on the uncertainty introduced by the tool when estimating bimorph deformations are given. Moreover, a case study that concerns the characterization of a piezoelectric bimorph actuator is discussed to illustrate the performance of the system developed in a real case.

A Low-Cost Experimental Setup to Characterize Piezoelectric Cantilever Bimorphs

ANDO', Bruno;GRAZIANI, Salvatore
2008-01-01

Abstract

Hysteresis is a common phenomenon in nonlinear systems. Piezoelectric bimorphs show hysteretic behavior when operating as actuators. Tools that produce the characterization of these devices are available; they use high-cost setups that measure deformations with resolutions on the order of nanometers. In this paper, a new low-cost experimental setup that uses coupled infrared detectors to investigate the behavior of piezoelectric actuators is discussed. The tool, providing deformation measurements with a resolution on the order of 10 ìm, is intended to produce a rough estimation of the device behavior and is of interest for research and educational purposes. Low cost, easy reproducibility in research and educational laboratories, a contactless measurement strategy, an inset calibration facility, and a suitable user interface are the main features of the tool developed. Notes on the uncertainty introduced by the tool when estimating bimorph deformations are given. Moreover, a case study that concerns the characterization of a piezoelectric bimorph actuator is discussed to illustrate the performance of the system developed in a real case.
2008
Piezoelectric; Characterization; low cost
File in questo prodotto:
File Dimensione Formato  
I&M_Piezo_2008_86.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: Non specificato
Dimensione 1.23 MB
Formato Adobe PDF
1.23 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/42096
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact