The main aim of this paper was to compare results of Genescan and real-time PCR methods in order to detect contamination in harvests from patients with follicular lymphoma. The secondary goal was to evaluate the efficacy of Rituximab as an in vivo purging agent. A total of 23 patients had been treated with CHOP followed by either high-dose therapy (12 patients) or high-dose plus Rituximab (11 patients), both followed by autologous transplantation. Results show that 86% of harvests from patients treated whith Rituximab were PCR-negative compared to 14.3% from controls. Real-time PCR was more sensitive than Genescan PCR; quantitative analysis revealed a correlation between the amount of contamination in the harvests and relapse after transplantation. Whereas all patients reinfused with negative aphereses achieved complete remission and showed a significantly better 5-year PFS (100%) compared to those reinfused with contaminated samples (41%), a very low amount of contamination does not appear to negatively affect outcome, suggesting that determination of a cutoff in the contamination level of harvests could be useful. Results suggest that real-time PCR is superior to Genescan PCR to select transplantable harvests and confirm the ability of Rituximab as an in vivo purging tool for follicular lymphoma

Quantitative molecular evaluation in autotransplant programs for follicular lymphoma: efficacy of in vivo purging by Rituximab

DI RAIMONDO, FRANCESCO;PALUMBO, Giuseppe Alberto Maria
2003-01-01

Abstract

The main aim of this paper was to compare results of Genescan and real-time PCR methods in order to detect contamination in harvests from patients with follicular lymphoma. The secondary goal was to evaluate the efficacy of Rituximab as an in vivo purging agent. A total of 23 patients had been treated with CHOP followed by either high-dose therapy (12 patients) or high-dose plus Rituximab (11 patients), both followed by autologous transplantation. Results show that 86% of harvests from patients treated whith Rituximab were PCR-negative compared to 14.3% from controls. Real-time PCR was more sensitive than Genescan PCR; quantitative analysis revealed a correlation between the amount of contamination in the harvests and relapse after transplantation. Whereas all patients reinfused with negative aphereses achieved complete remission and showed a significantly better 5-year PFS (100%) compared to those reinfused with contaminated samples (41%), a very low amount of contamination does not appear to negatively affect outcome, suggesting that determination of a cutoff in the contamination level of harvests could be useful. Results suggest that real-time PCR is superior to Genescan PCR to select transplantable harvests and confirm the ability of Rituximab as an in vivo purging tool for follicular lymphoma
File in questo prodotto:
File Dimensione Formato  
Quantitative molecular evaluation in autotransplant programs for follicular lymphoma.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 335.6 kB
Formato Adobe PDF
335.6 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/44626
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 32
social impact