Objectives This study evaluated the results of transcatheter aortic valve replacement (TAVR) in bicuspid aortic stenosis (AS) using a new-generation TAVR device. Background A bicuspid AS is often considered a relative contraindication to TAVR. Although initial reports have demonstrated feasibility using early-generation devices, outcomes have not matched those seen with tricuspid AS. Paravalvular aortic regurgitation (AR) has been particularly problematic. Methods We collected baseline characteristics, procedural data, and 30-day clinical follow-up findings from 8 centers in Europe and Canada that had performed TAVR in bicuspid AS using the SAPIEN 3 valve. Results 51 patients underwent TAVR using the SAPIEN 3 valve. Patient mean age was 76.2 ± 9.3 years and the Society of Thoracic Surgeons predicted risk of mortality scores were 5.2 ± 3.7%. Bicuspid valve types were: type 0, 11.8%; type 1, 82.3%; and type 2, 1.9%. There were no cases of valve embolization or need for a second valve. Post-dilation was performed in 7.8%. The mean aortic gradient decreased from 49.4 ± 16.0 mm Hg to 11.2 ± 4.7 mm Hg. Post-implantation AR was none/trivial in 63% and mild in 37%. There were no cases of moderate or severe AR. At 30-day follow-up, there were 2 deaths (3.9%), 2 major vascular complications, and 12 patients (23.5%) required pacemaker implantation. Conclusions TAVR in bicuspid AS using a new-generation device was feasible and effective with favorable valve performance and no cases of moderate or severe AR.

Bicuspid Aortic Valve Stenosis: Favorable Early Outcomes With a Next-Generation Transcatheter Heart Valve in a Multicenter Study.

TAMBURINO, Corrado;
2016-01-01

Abstract

Objectives This study evaluated the results of transcatheter aortic valve replacement (TAVR) in bicuspid aortic stenosis (AS) using a new-generation TAVR device. Background A bicuspid AS is often considered a relative contraindication to TAVR. Although initial reports have demonstrated feasibility using early-generation devices, outcomes have not matched those seen with tricuspid AS. Paravalvular aortic regurgitation (AR) has been particularly problematic. Methods We collected baseline characteristics, procedural data, and 30-day clinical follow-up findings from 8 centers in Europe and Canada that had performed TAVR in bicuspid AS using the SAPIEN 3 valve. Results 51 patients underwent TAVR using the SAPIEN 3 valve. Patient mean age was 76.2 ± 9.3 years and the Society of Thoracic Surgeons predicted risk of mortality scores were 5.2 ± 3.7%. Bicuspid valve types were: type 0, 11.8%; type 1, 82.3%; and type 2, 1.9%. There were no cases of valve embolization or need for a second valve. Post-dilation was performed in 7.8%. The mean aortic gradient decreased from 49.4 ± 16.0 mm Hg to 11.2 ± 4.7 mm Hg. Post-implantation AR was none/trivial in 63% and mild in 37%. There were no cases of moderate or severe AR. At 30-day follow-up, there were 2 deaths (3.9%), 2 major vascular complications, and 12 patients (23.5%) required pacemaker implantation. Conclusions TAVR in bicuspid AS using a new-generation device was feasible and effective with favorable valve performance and no cases of moderate or severe AR.
File in questo prodotto:
File Dimensione Formato  
Bicuspid Aortic Valve Stenosis.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Dimensione 528.19 kB
Formato Adobe PDF
528.19 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/47192
Citazioni
  • ???jsp.display-item.citation.pmc??? 42
  • Scopus 158
  • ???jsp.display-item.citation.isi??? 143
social impact