Background: Nocturnal hypoxemia adversely affects outcomes in patients with cystic fibrosis (CF). Although an early detection of this abnormality may be desirable, still its predictability remains uncertain. The Lung Clearance Index (LCI) is a measure of lung ventilation distribution obtained from a multiple-breath washout technique (MBW), recently implemented in patients with CF. This study aimed to establish whether the LCI predicts nocturnal hypoxemia in patients with stable CF, with mild to moderate disease, and normal diurnal gas exchange. Methods: 31 stable patients (15 males, mean age 17.4 ± 5.2 years) with mild to moderate CF, normoxic when awake, were enrolled. In all patients we performed nocturnal cardio-respiratory polygraphy, lung function measurement, and MBW test to derive LCI values. Results: LCI was abnormal in most of the patients and inversely correlated with mean nocturnal SpO2 (r = −0.880 p < 0.01). A receiver operating characteristic (ROC) analysis, performed to assess whether LCI predicted nocturnal hypoxemia, revealed a high predictive accuracy of LCI for nocturnal desaturation (AUC = 0.96; Youden index = 0.79). Forced expiratory volume in 1 s (FEV1) was predictive only in patients with more severe airway obstruction, with a moderate degree of accuracy (AUC 0.71). Conclusions: The LCI showed a high effectiveness in predicting nocturnal hypoxemia in stable patients with CF, particularly when compared with a traditional parameter of lung function such as FEV1.

Lung clearance index evaluation in detecting nocturnal hypoxemia in cystic fibrosis patients: Toward a new diagnostic tool

Papale M.;Parisi G. F.;Spicuzza L.;Bongiovanni A.;Leonardi S.
2020-01-01

Abstract

Background: Nocturnal hypoxemia adversely affects outcomes in patients with cystic fibrosis (CF). Although an early detection of this abnormality may be desirable, still its predictability remains uncertain. The Lung Clearance Index (LCI) is a measure of lung ventilation distribution obtained from a multiple-breath washout technique (MBW), recently implemented in patients with CF. This study aimed to establish whether the LCI predicts nocturnal hypoxemia in patients with stable CF, with mild to moderate disease, and normal diurnal gas exchange. Methods: 31 stable patients (15 males, mean age 17.4 ± 5.2 years) with mild to moderate CF, normoxic when awake, were enrolled. In all patients we performed nocturnal cardio-respiratory polygraphy, lung function measurement, and MBW test to derive LCI values. Results: LCI was abnormal in most of the patients and inversely correlated with mean nocturnal SpO2 (r = −0.880 p < 0.01). A receiver operating characteristic (ROC) analysis, performed to assess whether LCI predicted nocturnal hypoxemia, revealed a high predictive accuracy of LCI for nocturnal desaturation (AUC = 0.96; Youden index = 0.79). Forced expiratory volume in 1 s (FEV1) was predictive only in patients with more severe airway obstruction, with a moderate degree of accuracy (AUC 0.71). Conclusions: The LCI showed a high effectiveness in predicting nocturnal hypoxemia in stable patients with CF, particularly when compared with a traditional parameter of lung function such as FEV1.
2020
Cystic fibrosis
Lung clearance index
Lung function test
Nocturnal hypoxemia
File in questo prodotto:
File Dimensione Formato  
Lung clearance index evaluation.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 657.07 kB
Formato Adobe PDF
657.07 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/481669
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact