Background The majority of transcatheter aortic valve implantation (TAVI) procedures are currently performed by percutaneous transfemoral approach. The potential contribution of the type of vascular closure device to the incidence of vascular complications is not clear. Aim To compare the efficacy of a Prostar XL-vs. Perclose ProGlide-based vascular closure strategy. Methods The ClOsure device iN TRansfemoral aOrtic vaLve implantation (CONTROL) multi-center study included 3138 consecutive percutaneous transfemoral TAVI patients, categorized according to vascular closure strategy: Prostar XL-(Prostar group) vs. Perclose ProGlide-based vascular closure strategy (ProGlide group). Propensity-score matching was used to assemble a cohort of patients with similar baseline characteristics. Results Propensity matching identified 944 well-matched patients (472 patient pairs). Composite primary end point of major vascular complications or in-hospital mortality occurred more frequently in Prostar group when compared with ProGlide group (9.5 vs. 5.1%, P = 0.016), and was driven by higher rates of major vascular complication (7.4 vs. 1.9%, P < 0.001) in the Prostar group. However, in-hospital mortality was similar between groups (4.9 vs. 3.5%, P = 0.2). Femoral artery stenosis occurred less frequently in the Prostar group (3.4 vs. 0.5%, P = 0.004), but overall, Prostar use was associated with higher rates of major bleeding (16.7 vs. 3.2%, P < 0.001), acute kidney injury (17.6 vs. 4.4%, P < 0.001) and with longer hospital stay (median 6 vs. 5 days, P = 0.007). Conclusions Prostar XL-based vascular closure in transfemoral TAVI procedures is associated with higher major vascular complication rates when compared with ProGlide; however, in-hospital mortality is similar with both devices. © 2015 Published on behalf of the European Society of Cardiology. All rights reserved.

Comparison of vascular closure devices for access site closure after transfemoral aortic valve implantation

TAMBURINO, Corrado;
2015-01-01

Abstract

Background The majority of transcatheter aortic valve implantation (TAVI) procedures are currently performed by percutaneous transfemoral approach. The potential contribution of the type of vascular closure device to the incidence of vascular complications is not clear. Aim To compare the efficacy of a Prostar XL-vs. Perclose ProGlide-based vascular closure strategy. Methods The ClOsure device iN TRansfemoral aOrtic vaLve implantation (CONTROL) multi-center study included 3138 consecutive percutaneous transfemoral TAVI patients, categorized according to vascular closure strategy: Prostar XL-(Prostar group) vs. Perclose ProGlide-based vascular closure strategy (ProGlide group). Propensity-score matching was used to assemble a cohort of patients with similar baseline characteristics. Results Propensity matching identified 944 well-matched patients (472 patient pairs). Composite primary end point of major vascular complications or in-hospital mortality occurred more frequently in Prostar group when compared with ProGlide group (9.5 vs. 5.1%, P = 0.016), and was driven by higher rates of major vascular complication (7.4 vs. 1.9%, P < 0.001) in the Prostar group. However, in-hospital mortality was similar between groups (4.9 vs. 3.5%, P = 0.2). Femoral artery stenosis occurred less frequently in the Prostar group (3.4 vs. 0.5%, P = 0.004), but overall, Prostar use was associated with higher rates of major bleeding (16.7 vs. 3.2%, P < 0.001), acute kidney injury (17.6 vs. 4.4%, P < 0.001) and with longer hospital stay (median 6 vs. 5 days, P = 0.007). Conclusions Prostar XL-based vascular closure in transfemoral TAVI procedures is associated with higher major vascular complication rates when compared with ProGlide; however, in-hospital mortality is similar with both devices. © 2015 Published on behalf of the European Society of Cardiology. All rights reserved.
File in questo prodotto:
File Dimensione Formato  
Comparison-of-vascular-closure-devices-for-access-site-closure-after-transfemoral-aortic-valve-implantation2015European-Heart-Journal.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Dimensione 510.52 kB
Formato Adobe PDF
510.52 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/48507
Citazioni
  • ???jsp.display-item.citation.pmc??? 20
  • Scopus 127
  • ???jsp.display-item.citation.isi??? 116
social impact