Reverse transcription.quantitative polymerase chain reaction (RT-qPCR) is the gold standard method for the diagnosis of COVID-19 infection. Due to pre-analytical and technical limitations, samples with low viral load are often misdiagnosed as false.negative samples. Therefore, it is important to evaluate other strategies able to overcome the limits of RT-qPCR. Blinded swab samples from two individuals diagnosed positive and negative for COVID-19 were analyzed by droplet digital PCR (ddPCR) and RT-qPCR in order to assess the sensitivity of both methods. Intercalation chemistries and a World Health Organization (WHO)/Center for Disease Control and Prevention (CDC)-approved probe for the SARS-CoV-2N gene were used. SYBR-Green RT-qPCR is not able to diagnose as positive samples with low viral load, while, TaqMan Probe RT-qPCR gave positive signals at very late Ct values. On the contrary, ddPCR showed higher sensitivity rate compared to RT-qPCR and both EvaGreen and probe ddPCR were able to recognize the sample with low viral load as positive even at 10-fold diluted concentration. In conclusion, ddPCR shows higher sensitivity and specificity compared to RT-qPCR for the diagnosis of COVID-19 infection in false-negative samples with low viral load. Therefore, ddPCR is strongly recommended in clinical practice for the diagnosis of COVID-19 and the follow-up of positive patients until complete remission.
Sensitivity assessment of droplet digital PCR for SARS-CoV-2 detection
Falzone L.;Musso N.;Gattuso G.;Bongiorno D.;Scalia G.;Libra M.;Stefani S.
2020-01-01
Abstract
Reverse transcription.quantitative polymerase chain reaction (RT-qPCR) is the gold standard method for the diagnosis of COVID-19 infection. Due to pre-analytical and technical limitations, samples with low viral load are often misdiagnosed as false.negative samples. Therefore, it is important to evaluate other strategies able to overcome the limits of RT-qPCR. Blinded swab samples from two individuals diagnosed positive and negative for COVID-19 were analyzed by droplet digital PCR (ddPCR) and RT-qPCR in order to assess the sensitivity of both methods. Intercalation chemistries and a World Health Organization (WHO)/Center for Disease Control and Prevention (CDC)-approved probe for the SARS-CoV-2N gene were used. SYBR-Green RT-qPCR is not able to diagnose as positive samples with low viral load, while, TaqMan Probe RT-qPCR gave positive signals at very late Ct values. On the contrary, ddPCR showed higher sensitivity rate compared to RT-qPCR and both EvaGreen and probe ddPCR were able to recognize the sample with low viral load as positive even at 10-fold diluted concentration. In conclusion, ddPCR shows higher sensitivity and specificity compared to RT-qPCR for the diagnosis of COVID-19 infection in false-negative samples with low viral load. Therefore, ddPCR is strongly recommended in clinical practice for the diagnosis of COVID-19 and the follow-up of positive patients until complete remission.File | Dimensione | Formato | |
---|---|---|---|
ijmm-46-03-0957.pdf
accesso aperto
Dimensione
571.13 kB
Formato
Adobe PDF
|
571.13 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.