Reverse transcription.quantitative polymerase chain reaction (RT-qPCR) is the gold standard method for the diagnosis of COVID-19 infection. Due to pre-analytical and technical limitations, samples with low viral load are often misdiagnosed as false.negative samples. Therefore, it is important to evaluate other strategies able to overcome the limits of RT-qPCR. Blinded swab samples from two individuals diagnosed positive and negative for COVID-19 were analyzed by droplet digital PCR (ddPCR) and RT-qPCR in order to assess the sensitivity of both methods. Intercalation chemistries and a World Health Organization (WHO)/Center for Disease Control and Prevention (CDC)-approved probe for the SARS-CoV-2N gene were used. SYBR-Green RT-qPCR is not able to diagnose as positive samples with low viral load, while, TaqMan Probe RT-qPCR gave positive signals at very late Ct values. On the contrary, ddPCR showed higher sensitivity rate compared to RT-qPCR and both EvaGreen and probe ddPCR were able to recognize the sample with low viral load as positive even at 10-fold diluted concentration. In conclusion, ddPCR shows higher sensitivity and specificity compared to RT-qPCR for the diagnosis of COVID-19 infection in false-negative samples with low viral load. Therefore, ddPCR is strongly recommended in clinical practice for the diagnosis of COVID-19 and the follow-up of positive patients until complete remission.

Sensitivity assessment of droplet digital PCR for SARS-CoV-2 detection

Falzone L.;Musso N.;Gattuso G.;Bongiorno D.;Scalia G.;Libra M.;Stefani S.
2020-01-01

Abstract

Reverse transcription.quantitative polymerase chain reaction (RT-qPCR) is the gold standard method for the diagnosis of COVID-19 infection. Due to pre-analytical and technical limitations, samples with low viral load are often misdiagnosed as false.negative samples. Therefore, it is important to evaluate other strategies able to overcome the limits of RT-qPCR. Blinded swab samples from two individuals diagnosed positive and negative for COVID-19 were analyzed by droplet digital PCR (ddPCR) and RT-qPCR in order to assess the sensitivity of both methods. Intercalation chemistries and a World Health Organization (WHO)/Center for Disease Control and Prevention (CDC)-approved probe for the SARS-CoV-2N gene were used. SYBR-Green RT-qPCR is not able to diagnose as positive samples with low viral load, while, TaqMan Probe RT-qPCR gave positive signals at very late Ct values. On the contrary, ddPCR showed higher sensitivity rate compared to RT-qPCR and both EvaGreen and probe ddPCR were able to recognize the sample with low viral load as positive even at 10-fold diluted concentration. In conclusion, ddPCR shows higher sensitivity and specificity compared to RT-qPCR for the diagnosis of COVID-19 infection in false-negative samples with low viral load. Therefore, ddPCR is strongly recommended in clinical practice for the diagnosis of COVID-19 and the follow-up of positive patients until complete remission.
2020
COVID-19
ddPCR
Diagnosis
RT-qPCR
SARS-CoV-2
sensitivity
File in questo prodotto:
File Dimensione Formato  
ijmm-46-03-0957.pdf

accesso aperto

Dimensione 571.13 kB
Formato Adobe PDF
571.13 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/488499
Citazioni
  • ???jsp.display-item.citation.pmc??? 110
  • Scopus 158
  • ???jsp.display-item.citation.isi??? 145
social impact