The application of superconformal Bi-catalyzed Au electrodeposition for void-free filling of recessed trenches in X-ray gratings used in phase contrast imaging is detailed. Filling of trenches with aspect ratio (height divided by width) up to 55 is demonstrated. Uniform bottom-up filling of patterned trench arrays across 100 mm (4 inch) diameter Si wafer is accomplished using a well-defined hydrodynamic flow field across the wafer surface. The filling process and microstructure are examined by scanning electron microscopy of cross-sectioned specimens. The importance of process optimization, from the design of potential (current) programming to electrolyte pH and concentrations of Na3Au(SO3)2 and Bi3+, for the filling of high aspect ratio trenches is demonstrated. X-ray phase contrast imaging is used to assay the quality and uniformity of the as-formed gratings as well as demonstrate their application to imaging biological tissue. Successful void-free Au filling of micrometer range pitch, high aspect ratio trenches in Si gratings promises to advance X-ray grating interferometry and its application to X-ray phase contrast imaging.

Pushing the limits of bottom-up gold filling for x-ray grating interferometry

Romano L.;
2020-01-01

Abstract

The application of superconformal Bi-catalyzed Au electrodeposition for void-free filling of recessed trenches in X-ray gratings used in phase contrast imaging is detailed. Filling of trenches with aspect ratio (height divided by width) up to 55 is demonstrated. Uniform bottom-up filling of patterned trench arrays across 100 mm (4 inch) diameter Si wafer is accomplished using a well-defined hydrodynamic flow field across the wafer surface. The filling process and microstructure are examined by scanning electron microscopy of cross-sectioned specimens. The importance of process optimization, from the design of potential (current) programming to electrolyte pH and concentrations of Na3Au(SO3)2 and Bi3+, for the filling of high aspect ratio trenches is demonstrated. X-ray phase contrast imaging is used to assay the quality and uniformity of the as-formed gratings as well as demonstrate their application to imaging biological tissue. Successful void-free Au filling of micrometer range pitch, high aspect ratio trenches in Si gratings promises to advance X-ray grating interferometry and its application to X-ray phase contrast imaging.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/497450
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? ND
social impact