In orthognathic surgery, the use of patient-specific osteosynthesis devices is a novel approach used to transfer the virtual surgical plan to the patient. The aim of this study is to analyse the quality of mandibular anatomy reproduction using a mandible-first mandibular-PSI guided procedure on 22 patients. Three different positioning guide designs were compared in terms of osteosynthesis plate positioning and mandibular anatomical outcome. PSIs and positioning guides were designed according to virtual surgical plan and 3D printed using biocompatible materials. A CBCT scan was performed 1 month after surgery and postoperative mandibular models were segmented for comparison against the surgical plan. A precision comparison was carried out among the three groups. Correlations between obtained rami and plates discrepancies and between planned rami displacements and obtained rami discrepancies were calculated. Intraoperatively, all PSIs were successfully applied. The procedure was found to be accurate in planned mandibular anatomy reproduction. Different guide designs did not differ in mandibular outcome precision. Plate positional discrepancies influenced the corresponding ramus position, mainly in roll angle and vertical translation. Ramus planned displacement was found to be a further potential source of inaccuracy, possibly due to osteosynthesis surface interference.

Validation of a patient-specific system for mandible-first bimaxillary surgery: ramus and implant positioning precision assessment and guide design comparison

Bianchi A.
Formal Analysis
;
2020-01-01

Abstract

In orthognathic surgery, the use of patient-specific osteosynthesis devices is a novel approach used to transfer the virtual surgical plan to the patient. The aim of this study is to analyse the quality of mandibular anatomy reproduction using a mandible-first mandibular-PSI guided procedure on 22 patients. Three different positioning guide designs were compared in terms of osteosynthesis plate positioning and mandibular anatomical outcome. PSIs and positioning guides were designed according to virtual surgical plan and 3D printed using biocompatible materials. A CBCT scan was performed 1 month after surgery and postoperative mandibular models were segmented for comparison against the surgical plan. A precision comparison was carried out among the three groups. Correlations between obtained rami and plates discrepancies and between planned rami displacements and obtained rami discrepancies were calculated. Intraoperatively, all PSIs were successfully applied. The procedure was found to be accurate in planned mandibular anatomy reproduction. Different guide designs did not differ in mandibular outcome precision. Plate positional discrepancies influenced the corresponding ramus position, mainly in roll angle and vertical translation. Ramus planned displacement was found to be a further potential source of inaccuracy, possibly due to osteosynthesis surface interference.
File in questo prodotto:
File Dimensione Formato  
Validation of a patient-specific system for mandible-first bimaxillary surgery.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 3.13 MB
Formato Adobe PDF
3.13 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/503453
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 7
social impact