A calculation model is proposed to assess the combined effects of hot oxidation and creep damage on the residual life of radiant tubes used in topping furnaces of petrochemical plants. Experimental measures of thickness loss due to hot oxidation were carried out on specimens made of ASTM A335 P5 steel for tubes, to define the correlation of the thickness reduction with operating temperature and time, which was subsequently applied to evaluate the residual life in creep conditions. The model resulted effective in formulating hypotheses on the tubes actual thermal history, and defining the range of operating conditions that guarantee a safe return to service. It has also proved effective to predict the service life span of new tubes in ideal stable operating temperature, confirming the need for scheduling periodic checks to detect the actual condition of the tubes. Finally, a procedure for decision-making on tube decommissioning in maintenance interventions is presented.

An experimentally-based procedure for residual life assessment of steel radiant tubes

Giudice F.;
2022-01-01

Abstract

A calculation model is proposed to assess the combined effects of hot oxidation and creep damage on the residual life of radiant tubes used in topping furnaces of petrochemical plants. Experimental measures of thickness loss due to hot oxidation were carried out on specimens made of ASTM A335 P5 steel for tubes, to define the correlation of the thickness reduction with operating temperature and time, which was subsequently applied to evaluate the residual life in creep conditions. The model resulted effective in formulating hypotheses on the tubes actual thermal history, and defining the range of operating conditions that guarantee a safe return to service. It has also proved effective to predict the service life span of new tubes in ideal stable operating temperature, confirming the need for scheduling periodic checks to detect the actual condition of the tubes. Finally, a procedure for decision-making on tube decommissioning in maintenance interventions is presented.
2022
Radiant tubes
ASTM 335 P5 steel
Hot corrosion rate
Creep
Residual life
File in questo prodotto:
File Dimensione Formato  
IJPVP 2022.pdf

solo gestori archivio

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Dimensione 4.3 MB
Formato Adobe PDF
4.3 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/521637
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact