The identification of gunshot residues (GSRs) on human body in firearm related fatalities may be essential for the evaluation of gunshot wounds and for the analysis of the shooting distance. The present study introduces the elemental analysis of the GSRs by inductively coupled plasma atomic emission spectrometer analysis (ICP-AES) performed on skin samples. ICP-AES was used to increase the accuracy of the analysis in gunshots fired from long and medium distance. In this experimental study, a series of 50 test shots have been performed in an open space with lateral wind protection. As target we used pig skin cut into 20. cm. ×. 20. cm squares. The firing distances were 0.2, 5, 50, 100 and 150. cm. To exclude environmental contamination, each skin sample was carefully washed with deionized water and dried at room temperature in a closed box before the shooting test. We choose 9. ×. 21 and the 7.65. mm calibers handguns, loaded with different ammunitions. At ICP-AES analysis a clearly decreasing trend in the quantity and the concentration of the different elements of GSR by increasing the firing distance for both the guns used in the test was evident for every portion of skin samples analyzed. The analytical results obtained by ICP-AES confirmed very high concentrations of Pb, Sb, and Ba in the close-range shots and low concentrations of these particles in the intermediate and distant shots. In particular, the concentration of Sb, Ba, and Pb was significantly different from loose values when the firing distance was 100-150. cm for both the 9. ×. 21 and the 7.65. mm calibers. © 2013 Elsevier Ireland Ltd.
Analytical and quantitative concentration of gunshot residues (Pb, Sb, Ba) to estimate entrance hole and shooting-distance using confocal laser microscopy and inductively coupled plasma atomic emission spectrometer analysis: An experimental study
Pomara C.;Fineschi V.
2013-01-01
Abstract
The identification of gunshot residues (GSRs) on human body in firearm related fatalities may be essential for the evaluation of gunshot wounds and for the analysis of the shooting distance. The present study introduces the elemental analysis of the GSRs by inductively coupled plasma atomic emission spectrometer analysis (ICP-AES) performed on skin samples. ICP-AES was used to increase the accuracy of the analysis in gunshots fired from long and medium distance. In this experimental study, a series of 50 test shots have been performed in an open space with lateral wind protection. As target we used pig skin cut into 20. cm. ×. 20. cm squares. The firing distances were 0.2, 5, 50, 100 and 150. cm. To exclude environmental contamination, each skin sample was carefully washed with deionized water and dried at room temperature in a closed box before the shooting test. We choose 9. ×. 21 and the 7.65. mm calibers handguns, loaded with different ammunitions. At ICP-AES analysis a clearly decreasing trend in the quantity and the concentration of the different elements of GSR by increasing the firing distance for both the guns used in the test was evident for every portion of skin samples analyzed. The analytical results obtained by ICP-AES confirmed very high concentrations of Pb, Sb, and Ba in the close-range shots and low concentrations of these particles in the intermediate and distant shots. In particular, the concentration of Sb, Ba, and Pb was significantly different from loose values when the firing distance was 100-150. cm for both the 9. ×. 21 and the 7.65. mm calibers. © 2013 Elsevier Ireland Ltd.File | Dimensione | Formato | |
---|---|---|---|
Analytical and quantitative concentration of gunshot.pdf
solo gestori archivio
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
2.06 MB
Formato
Adobe PDF
|
2.06 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.