The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A 4 x 4 array of final design modules showed an energy resolution of about 11%/root E(GeV) circle plus 1.7% with a uniformity of the response to electrons of 1% and a good linearity in the energy range from 10 to 100 GeV. The electromagnetic shower position resolution was found to be described by 1.5 min circle plus 5.3 mm/root E(GeV). For an electron identification efficiency of 90% a hadron rejection factor of >600 was obtained. (C) 2009 Elsevier B.V. All rights reserved.

Performance of prototypes for the ALICE electromagnetic calorimeter

LA ROCCA, PAOLA;NOTO, FRANCESCO;PETTA, Catia Maria Annunziata;RIGGI, Francesco;
2010-01-01

Abstract

The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A 4 x 4 array of final design modules showed an energy resolution of about 11%/root E(GeV) circle plus 1.7% with a uniformity of the response to electrons of 1% and a good linearity in the energy range from 10 to 100 GeV. The electromagnetic shower position resolution was found to be described by 1.5 min circle plus 5.3 mm/root E(GeV). For an electron identification efficiency of 90% a hadron rejection factor of >600 was obtained. (C) 2009 Elsevier B.V. All rights reserved.
File in questo prodotto:
File Dimensione Formato  
NIMA50960 - PERFORMANCE OF PROTOTIPE.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 557.15 kB
Formato Adobe PDF
557.15 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/54826
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 22
social impact