Cyanide is a poison widely used in cases of suicide or homicide. Although various methods to identify and quantify this substance are reported in the literature, they are mainly validated on biological fluids (e.g., blood and urine). In the present study, the Anion-Exchange Liquid Chromatography with Pulsed Amperometric Detection (IC-PAD) method was validated on blood and, for the first time, on gastric content, and organs (brain, lung, and liver). For each matrix, linearity, accuracy, precision, limit of detection (LOD), lower limit of quantification (LLOQ), matrix interferences, and carryover were assessed. The samples were extracted by steam distillation in acid environment for the following analysis by IC-PAD. Furthermore, cyanide values found in two real poisoning cases are reported. For each investigated matrix, the analytical method satisfied all acceptance criteria for validation: it showed a good precision and accuracy, selectivity, and sensitivity with no carryover and matrix interference. The extraction by steam distillation in acid environment REDUCED the interference of the matrices and ALLOWED to perform the analysis with good precision and accuracy. In case #1, analysis showed a blood cyanide concentration of 0.99 μg/ml. In case #2, cyanide concentrations were 1.3 μg/g in brain, 0.8 μg/g in lung, 1.6 μg/g in liver, and 1.2 μg/g in gastric content. The cyanide concentrations found in the two reported cases have been suitable to cause death by poisoning.

Diagnosis of lethal cyanide poisoning. Analysis by Anion-Exchange Chromatography with Pulsed Amperometric Detection

Zuccarello, Pietro
Primo
Conceptualization
;
Carnazza, Giulia
Secondo
Methodology
;
Barbera, Nunziata
Ultimo
Conceptualization
2022-01-01

Abstract

Cyanide is a poison widely used in cases of suicide or homicide. Although various methods to identify and quantify this substance are reported in the literature, they are mainly validated on biological fluids (e.g., blood and urine). In the present study, the Anion-Exchange Liquid Chromatography with Pulsed Amperometric Detection (IC-PAD) method was validated on blood and, for the first time, on gastric content, and organs (brain, lung, and liver). For each matrix, linearity, accuracy, precision, limit of detection (LOD), lower limit of quantification (LLOQ), matrix interferences, and carryover were assessed. The samples were extracted by steam distillation in acid environment for the following analysis by IC-PAD. Furthermore, cyanide values found in two real poisoning cases are reported. For each investigated matrix, the analytical method satisfied all acceptance criteria for validation: it showed a good precision and accuracy, selectivity, and sensitivity with no carryover and matrix interference. The extraction by steam distillation in acid environment REDUCED the interference of the matrices and ALLOWED to perform the analysis with good precision and accuracy. In case #1, analysis showed a blood cyanide concentration of 0.99 μg/ml. In case #2, cyanide concentrations were 1.3 μg/g in brain, 0.8 μg/g in lung, 1.6 μg/g in liver, and 1.2 μg/g in gastric content. The cyanide concentrations found in the two reported cases have been suitable to cause death by poisoning.
2022
IC-PAD
blood
cyanide
forensic toxicology
gastric content
organs
validation
File in questo prodotto:
File Dimensione Formato  
JFO-67-1617.pdf

accesso aperto

Descrizione: Diagnosis of lethal cyanide poisoning. Analysis by Anion-Exchange Chromatography with Pulsed Amperometric Detection
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 602.25 kB
Formato Adobe PDF
602.25 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/549523
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 3
social impact