The purpose of this study was to evaluate the survival rate and incidence of prosthetic complications in 377 implants with a double octagon connection. Furthermore, the correlations among implant dimensions (diameter and length), bone quality, and insertion torque were investigated. A 4-year multicenter prospective clinical study was designed to evaluate the survival rate of 377 dental implants inserted in 189 patients between January 2004 and April 2010. After an average follow-up of 46 months, the implant survival rate was 99.7%, and the incidence of complication was 0.53%. Moreover, insertion torque was statistically related in a significant way to implant diameter. The connection system seemed to reduce the risk that the prosthetic component screw would loosen. Within the limits of this study, it was observed that a wider diameter corresponded to a higher implant primary stability. Implant length did not seem to be critical in obtaining higher primary stability.

A four-year survival rate multicenter prospective clinical study on 377 implants: Correlations between implant insertion torque, diameter, and bone quality

CICCIU', Marco;
2015-01-01

Abstract

The purpose of this study was to evaluate the survival rate and incidence of prosthetic complications in 377 implants with a double octagon connection. Furthermore, the correlations among implant dimensions (diameter and length), bone quality, and insertion torque were investigated. A 4-year multicenter prospective clinical study was designed to evaluate the survival rate of 377 dental implants inserted in 189 patients between January 2004 and April 2010. After an average follow-up of 46 months, the implant survival rate was 99.7%, and the incidence of complication was 0.53%. Moreover, insertion torque was statistically related in a significant way to implant diameter. The connection system seemed to reduce the risk that the prosthetic component screw would loosen. Within the limits of this study, it was observed that a wider diameter corresponded to a higher implant primary stability. Implant length did not seem to be critical in obtaining higher primary stability.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/553771
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 25
social impact