PurposeTo analyze as the primary endpoint the accuracy, sensitivity, and specificity of the SNOT-22 assessing CRS severity and to compare the results with a version of the SNOT-8 obtained from the nasal domain items.MethodsData were obtained from a prospective multicenter controlled study of dupilumab in adults with moderate-severe CRSwNP. EQUATOR and STROBE network guidelines were adopted. A multivariate logistic regression model was used to evaluate the accuracy of the model with the full (SNOT-22) and reduced (SNOT-8) item set to predict the severity outcome.ResultsSNOT-22 demonstrated an AUC of 0.885 (95% CI 0.825, - 0.945), and sensitivity and specificity of 91.49% (83.92-96.25%) and 69.23% (48.21-85.67%), respectively. Interestingly, after stepwise items elimination good outcomes were reported for SNOT-8, with an AUC of 0.818 (95% CI 0.744-0.892), achieving a sensitivity of 93.51% (85.49-97.86%) and specificity of 57.14% (40.96-72.28%).ConclusionPsychometric analyses support the accuracy, sensitivity, and specificity of the nasal domains of SNOT-22 to assess the impact on HRQoL in patients with CRSwNP.
Sensibility, specificity, and accuracy of the Sinonasal Outcome Test 8 (SNOT-8) in patients with chronic rhinosinusitis (CRS): a cross-sectional cohort study
La Mantia, IgnazioPrimo
Membro del Collaboration Group
;Ragusa, Martina;Grigaliute, Egle;Cocuzza, Salvatore;Riela, Paolo Marco;Maniaci, Antonino
Ultimo
Membro del Collaboration Group
2023-01-01
Abstract
PurposeTo analyze as the primary endpoint the accuracy, sensitivity, and specificity of the SNOT-22 assessing CRS severity and to compare the results with a version of the SNOT-8 obtained from the nasal domain items.MethodsData were obtained from a prospective multicenter controlled study of dupilumab in adults with moderate-severe CRSwNP. EQUATOR and STROBE network guidelines were adopted. A multivariate logistic regression model was used to evaluate the accuracy of the model with the full (SNOT-22) and reduced (SNOT-8) item set to predict the severity outcome.ResultsSNOT-22 demonstrated an AUC of 0.885 (95% CI 0.825, - 0.945), and sensitivity and specificity of 91.49% (83.92-96.25%) and 69.23% (48.21-85.67%), respectively. Interestingly, after stepwise items elimination good outcomes were reported for SNOT-8, with an AUC of 0.818 (95% CI 0.744-0.892), achieving a sensitivity of 93.51% (85.49-97.86%) and specificity of 57.14% (40.96-72.28%).ConclusionPsychometric analyses support the accuracy, sensitivity, and specificity of the nasal domains of SNOT-22 to assess the impact on HRQoL in patients with CRSwNP.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.