To examine the feasibility of performing pelvic lymphadenectomy with robotic single site approach. Recent papers described the feasibility of robotic-single site hysterectomy [1-3] for benign and malign pathologies but only with the development of new single site 5mm instruments as the bipolar forceps, robotic single site platform can be safely utilized also for lymphadenectomy. A 65 year-old, multiparous patient with a body mass index of 22.5 and diagnosed with well differentiated adenocarcinoma of the endometrium underwent a robotic single-site peritoneal washing, total hysterectomy, bilateral adnexectomy and pelvic lymphadenectomy. The procedure was performed using the da Vinci Si Surgical System (Intuitive Surgical, Sunnyvale, CA) through a single 2,5 cm umbilical incision, with a multi-channel system and two single site robotic 5mm instruments. A 3-dimensional, HD 8.5mm endoscope and a 5mm accessory instrument were also utilized. Type I lymphonodes dissection for external iliac and obturator regions was performed [4]. Total operative time was 210 min; incision, trocar placement and docking time occurring in 12 min. Total console time was 183 min, estimated blood loss was 50 ml, no intra-operative or post-operative complications occurred. Hospital discharge occurred on post operative day 2 and total number of lymphnodes removed was 33. Difficulties in term of instrument's clashing and awkward motions have been encountered. Robotic single-site pelvic lymphadenectomy using bipolar forceps and monopolar hook is feasible. New developments are needed to improve surgical ergonomics and additional studies should be performed to explore possible benefits of this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

Robotic single-site pelvic lymphadenectomy

Mereu L.
2014-01-01

Abstract

To examine the feasibility of performing pelvic lymphadenectomy with robotic single site approach. Recent papers described the feasibility of robotic-single site hysterectomy [1-3] for benign and malign pathologies but only with the development of new single site 5mm instruments as the bipolar forceps, robotic single site platform can be safely utilized also for lymphadenectomy. A 65 year-old, multiparous patient with a body mass index of 22.5 and diagnosed with well differentiated adenocarcinoma of the endometrium underwent a robotic single-site peritoneal washing, total hysterectomy, bilateral adnexectomy and pelvic lymphadenectomy. The procedure was performed using the da Vinci Si Surgical System (Intuitive Surgical, Sunnyvale, CA) through a single 2,5 cm umbilical incision, with a multi-channel system and two single site robotic 5mm instruments. A 3-dimensional, HD 8.5mm endoscope and a 5mm accessory instrument were also utilized. Type I lymphonodes dissection for external iliac and obturator regions was performed [4]. Total operative time was 210 min; incision, trocar placement and docking time occurring in 12 min. Total console time was 183 min, estimated blood loss was 50 ml, no intra-operative or post-operative complications occurred. Hospital discharge occurred on post operative day 2 and total number of lymphnodes removed was 33. Difficulties in term of instrument's clashing and awkward motions have been encountered. Robotic single-site pelvic lymphadenectomy using bipolar forceps and monopolar hook is feasible. New developments are needed to improve surgical ergonomics and additional studies should be performed to explore possible benefits of this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.
2014
Single-site robotic laparoscopy
Lymphadenectomy
Single port
Robotics
File in questo prodotto:
File Dimensione Formato  
Robotic single-site pelvic lymphadenectomy.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 126.78 kB
Formato Adobe PDF
126.78 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/559183
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 17
social impact