Objective The aim of this study is to verify if there are correlations between quantitative chest tomography (QCT) indexes and disease activity (DA) in a cohort of patients with systemic sclerosis (SSc). Methods SSc patients were assessed for DA and underwent high resolution chest tomography (CT). CT images were analysed with an operator-independent algorithm extracting the QCT indexes. DA assessment was conducted according to the EUSTAR index, where a score ≥2.5 indicates high DA (hDA). Correlations between clinical data and QCT indexes were investigated with the Spearman's test. The Mann-Whitney test assessed the distribution of the QCT indexes among the groups. Receiver operating characteristics (ROC) curve and linear regression analysis were conducted in order to identify the best cut-off value and contribution for each QCT index in assessing hDA in SSc patients. Results Sixty patients (52 females, mean age 53.2 years, mean disease duration 5.3 years) were enrolled. A significant difference was found in QCT indexes distribution between patients with hDA and those with low DA. A mild strength correlation between QCT indexes and DA was observed. Once performed ROC curves and linear regression, Skewness on parenchymal lung <1.85 gave a significant contribution to the model in identifying subjects with hDA (p<0.001), showing sensitivity 79.5%, specificity 68.7%, and accuracy 76.6%. Conclusion QCT indexes correlate with SSc DA. These data introduce new possibilities for QCT application in clinical practice, especially in patient's follow-up. Moreover, QCT could be implemented in a new SSc DA score based on operator- independent parameters.
Quantitative chest tomography indexes are related to disease activity in systemic sclerosis: results from a cross-sectional study
Sambataro G.Secondo
Conceptualization
;Palmucci S.Methodology
;Colaci M.Membro del Collaboration Group
;Malatino L.Membro del Collaboration Group
;
2022-01-01
Abstract
Objective The aim of this study is to verify if there are correlations between quantitative chest tomography (QCT) indexes and disease activity (DA) in a cohort of patients with systemic sclerosis (SSc). Methods SSc patients were assessed for DA and underwent high resolution chest tomography (CT). CT images were analysed with an operator-independent algorithm extracting the QCT indexes. DA assessment was conducted according to the EUSTAR index, where a score ≥2.5 indicates high DA (hDA). Correlations between clinical data and QCT indexes were investigated with the Spearman's test. The Mann-Whitney test assessed the distribution of the QCT indexes among the groups. Receiver operating characteristics (ROC) curve and linear regression analysis were conducted in order to identify the best cut-off value and contribution for each QCT index in assessing hDA in SSc patients. Results Sixty patients (52 females, mean age 53.2 years, mean disease duration 5.3 years) were enrolled. A significant difference was found in QCT indexes distribution between patients with hDA and those with low DA. A mild strength correlation between QCT indexes and DA was observed. Once performed ROC curves and linear regression, Skewness on parenchymal lung <1.85 gave a significant contribution to the model in identifying subjects with hDA (p<0.001), showing sensitivity 79.5%, specificity 68.7%, and accuracy 76.6%. Conclusion QCT indexes correlate with SSc DA. These data introduce new possibilities for QCT application in clinical practice, especially in patient's follow-up. Moreover, QCT could be implemented in a new SSc DA score based on operator- independent parameters.File | Dimensione | Formato | |
---|---|---|---|
Sambataro 2022.pdf
solo gestori archivio
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
784.56 kB
Formato
Adobe PDF
|
784.56 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.