Introduction: The present study aimed to investigate the effectiveness of low-level laser therapy (LLLT) use before in-office bleaching to prevent an increase in the risk and intensity of tooth sensitivity. Methods: Thirty patients were selected. Before bleaching with 38% hydrogen peroxide, the participants were randomly divided into two groups of 15 subjects. Test group: the patients’ teeth were subjected to a preliminary LLLT procedure by an 810 nm diode laser with 0.5 W for 30 s for an energy density of 15 J/cm2 and a group placebo. All patients were instructed to report their cold sensitivity experiences immediately, 1 h, 24 h, and 48 h after the end of bleaching via a VAS score. Results: The results obtained show an increase in VAS values for both groups (290 and 490 vs. 224 and 234 of baseline time of test and placebo group, respectively); afterward, the VAS value seemingly decreases at 1 h after the end of bleaching, approaching the baseline VAS for the test group (274) in comparison to the placebo group. Conclusions: The use of preliminary diode LLLT could represent a valid possibility to reduce the occurrence of tooth sensitivity post-whitening and shorten recovery time in cases where tooth sensitivity occurs.

The Use of Diode Low-Power Laser Therapy before In-Office Bleaching to Prevent Bleaching-Induced Tooth Sensitivity: A Clinical Double-Blind Randomized Study

Lo Giudice A.
;
2023-01-01

Abstract

Introduction: The present study aimed to investigate the effectiveness of low-level laser therapy (LLLT) use before in-office bleaching to prevent an increase in the risk and intensity of tooth sensitivity. Methods: Thirty patients were selected. Before bleaching with 38% hydrogen peroxide, the participants were randomly divided into two groups of 15 subjects. Test group: the patients’ teeth were subjected to a preliminary LLLT procedure by an 810 nm diode laser with 0.5 W for 30 s for an energy density of 15 J/cm2 and a group placebo. All patients were instructed to report their cold sensitivity experiences immediately, 1 h, 24 h, and 48 h after the end of bleaching via a VAS score. Results: The results obtained show an increase in VAS values for both groups (290 and 490 vs. 224 and 234 of baseline time of test and placebo group, respectively); afterward, the VAS value seemingly decreases at 1 h after the end of bleaching, approaching the baseline VAS for the test group (274) in comparison to the placebo group. Conclusions: The use of preliminary diode LLLT could represent a valid possibility to reduce the occurrence of tooth sensitivity post-whitening and shorten recovery time in cases where tooth sensitivity occurs.
2023
in-office bleaching
low-level laser therapy (LLLT)
pain
tooth sensitivity
File in questo prodotto:
File Dimensione Formato  
dentistry-11-00176.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 426.65 kB
Formato Adobe PDF
426.65 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/587439
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact