Background: Subjects with bicuspid aortic valve (BAV) have been excluded from transcatheter aortic valve replacement (TAVR) randomized trials.Methods: With this meta-analysis of observational studies we first compared TAVR outcomes of BAV vs. tricuspid aortic valve (TAV) patients, stratifying the results by device generation. Then, we looked for differences between balloon-expandable (BE) and self-expandable (SE) bioprostheses in BAV patients. Primary outcome was 30-day mortality. Secondary outcomes were 30-day stroke, moderate-severe paravalvular leakage, new pacemaker implantation, vascular complications and 1-year mortality.Results: Thirteen studies (11,032 patients, 7291 TAV and 3741 BAV) and seven studies (706 patients, 367 treated with BE, 339 with SE valve) met inclusion criteria. Thirty-day (OR = 1.13; 95% CI 0.88-1.46, p = 0.33) and 1-year mortality (OR = 1.02; 95% CI 0.77-1.37, p = 0.87) were similar between patients receiving TAVR for BAV or TAV. Subjects treated for BAV were at higher risk of conversion to conventional surgery (OR = 2.35; 95% CI 1.30-4.23, p = 0.005), implantation of a second valve (OR = 2.06; 95% CI 1.31-3.25; p = 0.002), moderate/severe paravalvular leakage (PVL) (OR = 1.67; 95% CI 1.29-2.17; p = 0.0001) and device failure (OR = 1.26; 95% CI 1.02-1.56; p = 0.04). Rates of adverse events decreased significantly with the use of new-generation devices, but outcome differences remained consistent. BAV patients treated with BE vs. SE valves had similar 30-day and 1-year mortality, stroke and moderate-severe PVL. Balloon-expandable valves were associated with lower rates of a second valve and new pacemaker implantation but carried higher risk of annular rupture.Conclusions: BAV patients treated with TAVR had similar 30-day and 1-year mortality as well as stroke and new pacemaker implantation rates compared to TAV subjects, but carried higher risk of moderate/severe PVL, conversion to surgery and device failure. Event rates significantly decreased with the use of new-generation devices, but TAVR still showed better procedural results in TAV compared to BAV. (C) 2019 Elsevier B.V. All rights reserved.

Transcatheter aortic valve replacement for bicuspid aortic valve stenosis with first- and new-generation bioprostheses: A systematic review and meta-analysis.

Giacoppo, Daniele;
2020-01-01

Abstract

Background: Subjects with bicuspid aortic valve (BAV) have been excluded from transcatheter aortic valve replacement (TAVR) randomized trials.Methods: With this meta-analysis of observational studies we first compared TAVR outcomes of BAV vs. tricuspid aortic valve (TAV) patients, stratifying the results by device generation. Then, we looked for differences between balloon-expandable (BE) and self-expandable (SE) bioprostheses in BAV patients. Primary outcome was 30-day mortality. Secondary outcomes were 30-day stroke, moderate-severe paravalvular leakage, new pacemaker implantation, vascular complications and 1-year mortality.Results: Thirteen studies (11,032 patients, 7291 TAV and 3741 BAV) and seven studies (706 patients, 367 treated with BE, 339 with SE valve) met inclusion criteria. Thirty-day (OR = 1.13; 95% CI 0.88-1.46, p = 0.33) and 1-year mortality (OR = 1.02; 95% CI 0.77-1.37, p = 0.87) were similar between patients receiving TAVR for BAV or TAV. Subjects treated for BAV were at higher risk of conversion to conventional surgery (OR = 2.35; 95% CI 1.30-4.23, p = 0.005), implantation of a second valve (OR = 2.06; 95% CI 1.31-3.25; p = 0.002), moderate/severe paravalvular leakage (PVL) (OR = 1.67; 95% CI 1.29-2.17; p = 0.0001) and device failure (OR = 1.26; 95% CI 1.02-1.56; p = 0.04). Rates of adverse events decreased significantly with the use of new-generation devices, but outcome differences remained consistent. BAV patients treated with BE vs. SE valves had similar 30-day and 1-year mortality, stroke and moderate-severe PVL. Balloon-expandable valves were associated with lower rates of a second valve and new pacemaker implantation but carried higher risk of annular rupture.Conclusions: BAV patients treated with TAVR had similar 30-day and 1-year mortality as well as stroke and new pacemaker implantation rates compared to TAV subjects, but carried higher risk of moderate/severe PVL, conversion to surgery and device failure. Event rates significantly decreased with the use of new-generation devices, but TAVR still showed better procedural results in TAV compared to BAV. (C) 2019 Elsevier B.V. All rights reserved.
2020
Balloon-expandable valve
Bicuspid aortic valve
Device generation
Self-expandable valve
Transcatheter aortic valve replacement
File in questo prodotto:
File Dimensione Formato  
Transcatheter aortic valve replacement for bicuspid aortic valve stenosis.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 921.74 kB
Formato Adobe PDF
921.74 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/590161
Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 48
  • ???jsp.display-item.citation.isi??? 44
social impact