The aim is to evaluate the feasibility of ultra-hypofractionated (UH) SBRT with CyberKnife® (CK) radiosurgery (Accuray Inc., Sunnyvale, California, USA) for localized prostate cancer (PCa) with a concomitant focal boost to the dominant intraprostatic lesion (DIL). Patients with intermediate/high-risk PCa, with at least one visible DIL on multi-parametric MRI, were included. For each, two CK-SBRT in silico plans were calculated using 95% and 85% isodose lines (CK-95%, CK-85%) and compared with the UH-DWA plan delivered with VERO®. All plans simulated a SIB prescription of 40 Gy to PTV-DIL and 36.25 Gy to the whole prostate (PTV-prostate) in five fractions every other day. Fifteen patients were considered. All plans reached the primary planning goal (D95% > 95%) and compliance with organs at risk (OARs) constraints. DVH metrics median values increased (p < 0.05) from UH-DWA to CK-85%. The conformity index of PTV-DIL was 1.00 for all techniques, while for PTV-prostate was 0.978, 0.984, and 0.991 for UH-DWA, CK-95%, and CK-85%, respectively. The CK-85% plans were able to reach a maximum dose of 47 Gy to the DIL while respecting OARs constraints. CK-SBRT plus a focal boost to the DIL for localized PCa appears to be feasible. These encouraging dosimetric results are to be confirmed in upcoming clinical trials such as the phase-II “PRO-SPEED” IEO trial.

CyberKnife Ultra-Hypofractionated SBRT for Localized Prostate Cancer with Dose Escalation to the Dominant Intraprostatic Lesion: In Silico Planning Study

Gallo S.;Petralia G.;
2023-01-01

Abstract

The aim is to evaluate the feasibility of ultra-hypofractionated (UH) SBRT with CyberKnife® (CK) radiosurgery (Accuray Inc., Sunnyvale, California, USA) for localized prostate cancer (PCa) with a concomitant focal boost to the dominant intraprostatic lesion (DIL). Patients with intermediate/high-risk PCa, with at least one visible DIL on multi-parametric MRI, were included. For each, two CK-SBRT in silico plans were calculated using 95% and 85% isodose lines (CK-95%, CK-85%) and compared with the UH-DWA plan delivered with VERO®. All plans simulated a SIB prescription of 40 Gy to PTV-DIL and 36.25 Gy to the whole prostate (PTV-prostate) in five fractions every other day. Fifteen patients were considered. All plans reached the primary planning goal (D95% > 95%) and compliance with organs at risk (OARs) constraints. DVH metrics median values increased (p < 0.05) from UH-DWA to CK-85%. The conformity index of PTV-DIL was 1.00 for all techniques, while for PTV-prostate was 0.978, 0.984, and 0.991 for UH-DWA, CK-95%, and CK-85%, respectively. The CK-85% plans were able to reach a maximum dose of 47 Gy to the DIL while respecting OARs constraints. CK-SBRT plus a focal boost to the DIL for localized PCa appears to be feasible. These encouraging dosimetric results are to be confirmed in upcoming clinical trials such as the phase-II “PRO-SPEED” IEO trial.
2023
CyberKnife
feasibility study
in silico planning
prostate cancer
ultra-hypofractionated SBRT
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/596712
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact