Objectives: to evaluate long-term effectiveness and safety of fluocinolone acetonide (FAc) implant used as second-line treatment in patients with persistent diabetic macular edema (DME). Methods: retrospective data chart review of 241 pseudophakic eyes of 178 patients treated with FAc from July 2017 to December 2021 in 10 medical retinal units in Italy. The primary endpoint was the change of best-corrected visual acuity (BCVA) and central macular thickness (CMT) at 2 years. A Student's paired t-test was used. Additional therapies for DME and intraocular pressure (IOP)-related events were also evaluated. Results: efficacy of FAc was assessed in a subset of 111 eyes with at least 24 months of follow-up. Mean BCVA increased at 2 years by 5.1 ETDRS letters (95%CI = 2.6-7.5; p < 0.001) while mean CMT decreased by 189 µm (95% CI 151-227; p < 0.001). Thirty-eight of these eyes (34.2%) needed additional intravitreal treatments, mainly anti-VEGF. Safety was evaluated on the entire cohort of 241 eyes treated with FAc. Overall, 66 eyes (27.4%) required emergent IOP-lowering medications (typically within the first-year post FAc) while 14 eyes (5.8%) underwent trabeculectomy, mostly during the second year of follow-up. Conclusion: FAc implant provides a substantial long-term functional and anatomical benefit when used as second-line treatment in eyes with DME. IOP rise can be adequately managed with topical agents although some eyes may require IOP-lowering surgery.

Real-world experience with fluocinolone acetonide intravitreal implant in patients with diabetic macular edema

Castellino, Nicolò;Ortisi, Elina;Reibaldi, Michele;
2024-01-01

Abstract

Objectives: to evaluate long-term effectiveness and safety of fluocinolone acetonide (FAc) implant used as second-line treatment in patients with persistent diabetic macular edema (DME). Methods: retrospective data chart review of 241 pseudophakic eyes of 178 patients treated with FAc from July 2017 to December 2021 in 10 medical retinal units in Italy. The primary endpoint was the change of best-corrected visual acuity (BCVA) and central macular thickness (CMT) at 2 years. A Student's paired t-test was used. Additional therapies for DME and intraocular pressure (IOP)-related events were also evaluated. Results: efficacy of FAc was assessed in a subset of 111 eyes with at least 24 months of follow-up. Mean BCVA increased at 2 years by 5.1 ETDRS letters (95%CI = 2.6-7.5; p < 0.001) while mean CMT decreased by 189 µm (95% CI 151-227; p < 0.001). Thirty-eight of these eyes (34.2%) needed additional intravitreal treatments, mainly anti-VEGF. Safety was evaluated on the entire cohort of 241 eyes treated with FAc. Overall, 66 eyes (27.4%) required emergent IOP-lowering medications (typically within the first-year post FAc) while 14 eyes (5.8%) underwent trabeculectomy, mostly during the second year of follow-up. Conclusion: FAc implant provides a substantial long-term functional and anatomical benefit when used as second-line treatment in eyes with DME. IOP rise can be adequately managed with topical agents although some eyes may require IOP-lowering surgery.
2024
Pharmacology &lt; PHARMACOLOGY
diabetic macular edema &lt; RETINA
diabetic retinopathy &lt; RETINA
glaucoma incisional surgery &lt; GLAUCOMA
glaucoma medical therapies &lt; GLAUCOMA
retina - medical therapies &lt; RETINA
File in questo prodotto:
File Dimensione Formato  
capone-et-al-2024-real-world-experience-with-fluocinolone-acetonide-intravitreal-implant-in-patients-with-diabetic.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/637109
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact