A pixelation method addresses the challenge of accurately assigning coordinates to each particle that impinges on the detector area. The pixelation method used for the analysis of the data acquired with Double-Sided Silicon Strip Detectors of the Femtoscope ARray for COrrelations and Spectroscopy FARCOS is described here. The application of the pixelation method requires several tasks to be performed. First, the coincidence in the detection time of the particles of front and back signals allows the elimination of spurious events. The second fundamental operation is the recovery of inter-strip events obtained comparing the energies of detected front and back side signals in all possible configurations. Two-alpha coincidences are analysed and the 8Beg.s. resonance is observed to compare the energy resolution of recovered inter-strip events with that of single-strip events. Using this pixelation method, a 41 ± 8% improvement in the efficiency of detecting three-alpha particles was achieved.

Pixelation method for the FARCOS array

Cardella G.;Martorana N. S.;D'Agata G.;De Filippo E.;Geraci E.;Gnoffo B.;Pagano E. V.;Rizzo F.;Russotto P.;Zagami C.
2024-01-01

Abstract

A pixelation method addresses the challenge of accurately assigning coordinates to each particle that impinges on the detector area. The pixelation method used for the analysis of the data acquired with Double-Sided Silicon Strip Detectors of the Femtoscope ARray for COrrelations and Spectroscopy FARCOS is described here. The application of the pixelation method requires several tasks to be performed. First, the coincidence in the detection time of the particles of front and back signals allows the elimination of spurious events. The second fundamental operation is the recovery of inter-strip events obtained comparing the energies of detected front and back side signals in all possible configurations. Two-alpha coincidences are analysed and the 8Beg.s. resonance is observed to compare the energy resolution of recovered inter-strip events with that of single-strip events. Using this pixelation method, a 41 ± 8% improvement in the efficiency of detecting three-alpha particles was achieved.
2024
Coincidence events
Correlation measurements
Energy resolution
Pattern recognition
Silicon strip detectors
File in questo prodotto:
File Dimensione Formato  
Pixelation method for the FARCOS array.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.96 MB
Formato Adobe PDF
2.96 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/641849
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact