A method for the analysis of [1-(4-aminophenyl)-3,5-dihydro-7,8-dimethoxy-4H-2,3-benzodiazepin-4-one] (CFM-2) and its analogues CFM-3, CFM-4 and CFM-5 in rat plasma was developed. The 2,3-benzodiazepines (2,3-BZs) were extracted by liquid-liquid extraction and analyzed using high-performance liquid chromatography (HPLC) with ultraviolet detection (UV) at 240 nm. The method exhibited a large linear range from 0.05 to 2 μg/ml with an intra-assay accuracy for all studied compounds ranging from 92 to 105.5%; whereas the intra-assay precision ranged from 0.59 to 8.16% in rat plasma. The inter-assay accuracy of CFM-2, CFM-4 and their 3-methyl derivatives, CFM-3 and CFM-5 ranged from 92.2 to 107% and the inter-assay precision ranged from 2.17 to 11.9% in rat plasma. The lower limit of detection was 5.5 ng/ml for CFM-2, 6.5 ng/ml for CFM-3, 7 ng/ml for CFM-4 and 8.5 ng/ml for CFM-5 in rat plasma. The pharmacokinetic study demonstrated that 2,3-BZs achieved a peak plasma concentration between 45 and 75 min after drug administration. Moreover, we observed that plasma chromatograms of rats treated with CFM-3, CFM-4 and CFM-5, respectively, showed a peak consistent with CFM-2. Our study suggests that CFM-4, CFM-5 and CFM-3 are prodrugs of CFM-2, in which they are biotransformed in vivo via different metabolic pathways. In particular, CFM-2 has been proven to possess anticonvulsant activity in various models of seizures, acting as α-amino-3-hydroxy-5-methyl-isoxazole-4-propionate (AMPA) receptor antagonist. Copyright (C) 1999 Elsevier Science B.V.

Determination of new 2,3-benzodiazepines in rat plasma using high-performance liquid chromatography with ultraviolet detection

Rizzo M.;
1999-01-01

Abstract

A method for the analysis of [1-(4-aminophenyl)-3,5-dihydro-7,8-dimethoxy-4H-2,3-benzodiazepin-4-one] (CFM-2) and its analogues CFM-3, CFM-4 and CFM-5 in rat plasma was developed. The 2,3-benzodiazepines (2,3-BZs) were extracted by liquid-liquid extraction and analyzed using high-performance liquid chromatography (HPLC) with ultraviolet detection (UV) at 240 nm. The method exhibited a large linear range from 0.05 to 2 μg/ml with an intra-assay accuracy for all studied compounds ranging from 92 to 105.5%; whereas the intra-assay precision ranged from 0.59 to 8.16% in rat plasma. The inter-assay accuracy of CFM-2, CFM-4 and their 3-methyl derivatives, CFM-3 and CFM-5 ranged from 92.2 to 107% and the inter-assay precision ranged from 2.17 to 11.9% in rat plasma. The lower limit of detection was 5.5 ng/ml for CFM-2, 6.5 ng/ml for CFM-3, 7 ng/ml for CFM-4 and 8.5 ng/ml for CFM-5 in rat plasma. The pharmacokinetic study demonstrated that 2,3-BZs achieved a peak plasma concentration between 45 and 75 min after drug administration. Moreover, we observed that plasma chromatograms of rats treated with CFM-3, CFM-4 and CFM-5, respectively, showed a peak consistent with CFM-2. Our study suggests that CFM-4, CFM-5 and CFM-3 are prodrugs of CFM-2, in which they are biotransformed in vivo via different metabolic pathways. In particular, CFM-2 has been proven to possess anticonvulsant activity in various models of seizures, acting as α-amino-3-hydroxy-5-methyl-isoxazole-4-propionate (AMPA) receptor antagonist. Copyright (C) 1999 Elsevier Science B.V.
1999
Benzodiazepines
File in questo prodotto:
File Dimensione Formato  
Determination of new 2,3-benzodiazepines in rat plasma.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 199.1 kB
Formato Adobe PDF
199.1 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/643851
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
social impact