Objectives: To evaluate the accuracy of three fully automated software systems compared to nonautomated cephalometric analysis software tested using cephalograms featuring correct and incorrect head positions. Materials and Methods: The study sample consisted of 40 lateral cephalograms retrieved retro-spectively from a larger pool of pretreatment orthodontic records. Cephalograms were recruited and divided into correct head posture group (CHP) and incorrect head posture group (IHP). Cephalometric data were obtained by manual landmarking (Dolphin software), which served as a reference, and by fully automated AI software (WebCeph, Ceph Assistant, and AudaxCeph). Intraclass correlation coefficients (ICC) and paired t-tests were used for intragroup comparisons, whereas analysis of variance and post-hoc analysis were used to compare performance among artificial intelligence (AI) based software applications. Results: The tested software exhibited a good level of consistency for angular measurements whereas linear measurements were more error-prone. AudaxCeph demonstrated the most con-sistent accuracy, achieving excellent agreement (ICC > 0.90) for several skeletal parameters; however, it failed in detecting soft tissue accurately. WebCeph and Ceph Assistant showed greater variability, especially for linear measurements (ICC < 0.50). Positional errors drastically reduced measurement accuracy, with linear parameters such as Go-Me showing the poorest agreement across all software. Conclusions: AI-based cephalometric software demonstrated variable accuracy depending on the cephalometric measurement, and this pattern was exacerbated under conditions involving positional errors in cephalograms. Accordingly, oversight by expert clinicians is still required to minimize marginal error. (Angle Orthod. 2025;95:619–628.).

Influence of head positioning errors on the accuracy of fully automated artificial intelligence-based cephalometric software

Polizzi, Alessandro
Primo
;
Lo Giudice, Antonino
Secondo
;
Conforte, Cristina;Isola, Gaetano
Penultimo
;
Leonardi, Rosalia
Ultimo
2025-01-01

Abstract

Objectives: To evaluate the accuracy of three fully automated software systems compared to nonautomated cephalometric analysis software tested using cephalograms featuring correct and incorrect head positions. Materials and Methods: The study sample consisted of 40 lateral cephalograms retrieved retro-spectively from a larger pool of pretreatment orthodontic records. Cephalograms were recruited and divided into correct head posture group (CHP) and incorrect head posture group (IHP). Cephalometric data were obtained by manual landmarking (Dolphin software), which served as a reference, and by fully automated AI software (WebCeph, Ceph Assistant, and AudaxCeph). Intraclass correlation coefficients (ICC) and paired t-tests were used for intragroup comparisons, whereas analysis of variance and post-hoc analysis were used to compare performance among artificial intelligence (AI) based software applications. Results: The tested software exhibited a good level of consistency for angular measurements whereas linear measurements were more error-prone. AudaxCeph demonstrated the most con-sistent accuracy, achieving excellent agreement (ICC > 0.90) for several skeletal parameters; however, it failed in detecting soft tissue accurately. WebCeph and Ceph Assistant showed greater variability, especially for linear measurements (ICC < 0.50). Positional errors drastically reduced measurement accuracy, with linear parameters such as Go-Me showing the poorest agreement across all software. Conclusions: AI-based cephalometric software demonstrated variable accuracy depending on the cephalometric measurement, and this pattern was exacerbated under conditions involving positional errors in cephalograms. Accordingly, oversight by expert clinicians is still required to minimize marginal error. (Angle Orthod. 2025;95:619–628.).
2025
AudaxCeph
Ceph Assistant
Cephalometric analysis
Dolphin
Fully automatic cephalometry
Orthodontics
WebCeph
File in questo prodotto:
File Dimensione Formato  
angl-article-p619.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 536.86 kB
Formato Adobe PDF
536.86 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11769/700750
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact